Plan Review Notes
Plan Review Notes For Permit 14041079
Permit Number 14041079
Review Stop B
Sequence Number 1
Notes
Date Text
2014-05-23 18:25:11RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 101.4.3 OF 2010 FBC-ENERGY CONSERVATION.
  
 2- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT
 FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 3- PROVIDE COMPLETE INFORMATION FOR THE FIREPLACE AND
 CHIMNEY AS REQUIRED BY CHAPTER 10 AND SEC. M1805 OF
 2010 FBC-RESIDENTIAL. (NOTE: CHECK CLEARANCE DIMENSION
 OF CHIMNEY FROM THE FINISH ROOF LINE AND REVISE PLANS
 AS REQUIRED).
  
 4- SPECIFY CARBON MONOXIDE ALARMS AS REQUIRED BY SEC.
 R315 OF 2010 FBC-RESIDENTIAL.
  
 5-SHEET S-2:
 A) CHIMNEY FRAMING DETAIL A/S-2: PROVIDE COMPLETE
 FRAMING INFORMATION (DETAIL AND SPECS) FOR CHIMNEY
 ATTACHMENT TO THE EXISTING ROOF TRUSS. SEC. 107.2.1.3
 CITY AMENDMENTS TO FBC. DRAWING SUBMITTED IS
 INCOMPLETE.
  
 B) THIRD NOTE OF THE WINDOW/MANDOOR BUCK DETAIL MASONRY
 OPENINGS SPECIFIES THAT NO STEEL IS REQUIRED ON THE
 OPENINGS FILLED CELLS. THIS NOTE DOESN'T MATCH
 INFORMATION SHOWN ON DETAIL A/S-4. REVISE AS REQUIRED
 TO MATCH. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) SHUTTERS SHOWN ON THE NORTH AND EAST ELEVATION. AND
 PROVIDE COMPLETE INSTALLATION SCHEDULE.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS,
 INCLUDING THE ONES SUBMITTED FOR THE DOORS/WINDOWS,
 ETC. SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES
 (561)805-6712


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved