2014-05-30 19:01:582010 FBC
  
 PLUMBING DENIED
  
 1) ALL OF THE UNITS THAT ARE SHOWN ON SHEET P1.0, HAVE
 IMPROPERLY VENTED BATHROOM GROUPS. SEE FBCR P3108.2.1
 HORIZONTAL WET VENT. NOT MORE THAN ONE WET-VENTED
 FIXTURE DRAIN SHALL DISCHARGE UP-STREAM OF THE
 DRY-VENTED FIXTURE DRAIN CONNECTION.
  
 2) ON THE MODEL F RISER DIAGRAM THE TUB IS NOT SHOWN AT
 THE END OF THE 2" HORIZONTAL DRAIN IN BATH #2. CITY
 AMENDMENTS 107.2.1
  
 3) ON THE MODEL A RISER DIAGRAM THE MASTER BATH SHOWER
 IS LABELED AS A TUB. CITY AMENDMENTS 107.2.1
  