2014-05-02 07:01:09 | PLUMBING PLAN REVIEW |
| REVISION: 14040884 |
| PERMIT: 13120972 |
| ADD: 5802 S DIXIE HWY. |
| CONT: MIKE MOORE |
| TEL: (561)301-9468 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. |
| ACTION: DENIED |
| |
| 1) THIS IS A EXSPANSION OF A INTERIOR- DEMO PERMIT TO |
| INCLUDE THE REBUILDING OF A RESTROOM. PLEASE PROVIDE |
| TYPE OF OCCUPANCY THIS UNIT IS TO BE CONSIDERED. NOTE |
| APPROXIMATELY 1386 SQ FT. |
| BUSSINESS 1386 SQ FT/ 100= 14 OCCUPANT LOAD 2010 FBC-P |
| 403.2 EXC 3 ALLOWS FOR A SINGLE UNISEX |
| MERCANTILE 1386 SQ FT / 30 = 47 OCCUPANT LOAD 2010 |
| FBC-P 403.2 EXC 3 ALLOWS FOR A SINGLE UNISEX |
| RESTARAUNT 1386 SQ FT/ 15= 93 OCCUPANT LOAD |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1 BUILDING |
| OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS |
| SHALL BE DETERMINED. |
| MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE |
| TABLE 503). |
| OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| OCCUPANCY LOAD |
| |
| 2A) THE PLANS INDICATE THE NEW RESTROOM PLUMBING GOING |
| INTO A EXISTING FIRE WALL, THE TYPE OF OCCUPANCY NEEDS |
| TO BE DECLARED TO KNOW WHAT RATING THE FIRE WALL NEEDS |
| TO BE RATED. PLEASE CONFIRM IF THIS IS A PARTYWALL |
| SHARED BY BOTH TENANTS OR IF THERE ARE TO TENANT |
| SEPERATION WALLS BACK TO BACK. IF THIS IS A SHARED |
| PARTYWALL THE PLUMBING WILL NOT BE ABLE TO BE PUT INTHE |
| PARTY WALL. FOR A TENANT SEPERATION WALL PLEASE SEE |
| 2010 FBC-B TABLES 602 EXTERIOR WALLS FIRE SEPERATION |
| DISTANCE AND TABLE 706.4 FIRE WALL RATINGS DETERMINED |
| BY OCCUPANCY GROUP. NOTE IF THE PLUMBING IS INSET INTO |
| THE FIRE WALL, WHAT TYPE OF MATERIAL IS GOING TO BE |
| USED TO BE INSTALLED TO COVER THE PIPES AND HAVE THE |
| SAME RATING AS THE FIRE WALL. |
| |
| 2B) 2010 FBC-B 706.8 FIREWALL OPENINGS. |
| EACH OPENING THROUGH A FIRE WALL SHALL BE PROTECTED IN |
| ACCORDANCE WITH SECTION 715.4 AND SHALL NOT EXCEED 156 |
| SQUARE FEET (15 M2). THE AGGREGATE WIDTH OF OPENINGS AT |
| ANY FLOOR LEVEL SHALL NOT EXCEED 25 PERCENT OF THE |
| LENGTH OF THE WALL. |
| EXCEPTIONS: |
| 1. OPENINGS ARE NOT PERMITTED IN PARTY WALLS |
| CONSTRUCTED IN ACCORDANCE WITH SECTION 706.1.1. |
| 2. OPENINGS SHALL NOT BE LIMITED TO 156 SQUARE FEET (15 |
| M2) WHERE BOTH BUILDINGS ARE EQUIPPED THROUGHOUT WITH |
| AN AUTOMATIC |
| SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION |
| 903.3.1.1. |
| |
| 2C) 706.9 FIREWALL PENETRATIONS. PENETRATIONS OF FIRE |
| WALLS SHALL COMPLY WITH SECTION 713. |
| |
| 2D) 2010 FBC-B 706.5.1 REQUIRES THERE TO BE NO |
| PENETRATIONS OF THE ROOF WITHIN THE TOTAL LENGTH OF THE |
| FIRE WALL, THE VENT WILL BE REQUIRED TO BE OFFSET. IN |
| NEW CONSTRUCTION THE ROOF DECK WOULD HAVE BEEN EITHER |
| FIRE RETARDANT TREATED PLYWOOD OR 5/8 INCH TYPE X |
| DRYWALL BELOW THE ROOF DECK. |
| |
| 2E) PLEASE PROVIDE WHAT TYPE OF FIRE RESISTANCE RATED |
| ASSEMBLY WILL BE INSTALLED WHERE THE PIPES PENETRATE |
| THE FIRE RATED WALL. |
| 2010 FBC-B 713.3.1.1. |
| |
| 3) PLEASE SEE ACCESSIBILITY DETAIL FLOOR PLAN INDICATES |
| THE WATER CLOSET A MINIMUM OF 12 INCHES FROM WALL LINE. |
| 2010 FL ACCESSIBILITY CODE 604.2 LOCATION. THE WATER |
| CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO |
| THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE WATER |
| CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM TO 18 INCHES |
| (455 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION, |
| EXCEPT THAT THE WATER CLOSET SHALL BE 17 INCHES (430 |
| MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM FROM THE |
| SIDE WALL OR PARTITION IN THE AMBULATORY ACCESSIBLE |
| TOILET COMPARTMENT SPECIFIED IN 604.8.2. WATER CLOSETS |
| SHALL BE ARRANGED FOR A LEFT-HAND OR RIGHT-HAND |
| APPROACH. |
| |