2014-04-23 14:24:32RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (2
 COPIES WITH ORIGINAL SEAL AND SIGNATURE) AS REQUIRED BY
 GENERAL LIMITATION #7 OF NOA 13-0424.14 SUBMITTED. NEED
 THE RAS 117 CALCULATIONS TO MEET THE PERIMETER AND
 CORNER AREAS REQUIRED BY SEC. 1609 FBC.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. SEC. 109.3 CITY AMENDMENTS TO FBC. VALUATION TO
 INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND
 PROFIT AND DESIGN PROFESSIONAL FEES. VALUATION WAS
 UPDATED TO $13,472. THE PERMIT FEE BALANCE IS $344.51.
  
 3- PROVIDE NOTICE OF COMMENCEMENT AS REQUIRED BY
 CHAPTER 713 FLORIDA STATUTE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712