Date Text
2014-04-21 13:07:08FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES.
  
 1) THE MOST RECENT SET OF ARCHITECTURAL SITE PLANS
 (REVISION DATE APRIL 2, 2014) WAS NOT PROVIDED WITH
 THIS PERMIT. CHANGES SHOWING THE CORRECT NUMBER OF
 PARKING SPACES IN THE NORTHEASTERN MOST EMPLOYEE
 PARKING AREA, THE NORTHERN MOST FIRE HYDRANT AND THE
 TRANSFORMER PAD HAVE NOT BEEN INCLUDED.
  
 2) THE ROOF PLAN, SHEET 118.1, INCORRECTLY LISTS 22
 (INSTEAD OF 24) PARKING SPACES. ADDITIONALLY, THE RACK,
 WITH CU-6, SHOWN ON MECHANICAL SHEET M3.2 IS NOT
 REFLECTED ON SHEET 118.1.
  
 3) THE FPL TRANSFORMER AND PAD ADJACENT TO THE TRASH
 COMPACTOR ARE SHOWN DIFFERENTLY ON THE SITE, CIVIL AND
 LANDSCAPE PLANS. THE SITE POWER PLAN SHOWS THE
 TRANSFORMER IN A COMPLETELY DIFFERENT LOCATION THAN THE
 OTHER THREE PLANS. ALL PLANS SHALL SHOW THE SAME
 CONDITION.
  
 4) SEPARATE PERMITS, WITH PLANS, ARE REQUIRED FOR THE
 FOLLOWING:
  
 A. LANDSCAPE - PLEASE NOTE THAT THE SUBMITTED LANDSCAPE
 PLAN IS NOT THE MOST RECENT LANDSCAPE PLAN.
  
 B. PARKING LOT STRIPING
  
 C. SITE LIGHTING - THE PHOTOMETRIC PLAN NEEDS TO SHOW
 COMPLIANCE WITH THE APPROVED DSI LIGHTING CONDITIONS.
 NO INFORMATION ON THE PROPOSED LIGHTS AND THE CUT-OFF
 FEATURES WAS PROVIDED. COMPLIANCE WITH THE DSI
 CONDITION LISTED IS NOT PROVIDED - THERE IS A VALUE
 SHOWN AT 2.1 FOOTCANDLES AT THREE (3) FEET ABOVE GRADE
 ALONG CHILLINGWORTH DRIVE
  
 DSI CONDITION: LIGHT TRESPASS FROM THE SITE SHALL NOT
 EXCEED 2.0 FOOTCANDLES AT THREE (3) FEET ABOVE GRADE
 WHEN MEASURED AT THE CURB ALONG OKEECHOBEE BOULEVARD
 AND CHILLINGWORTH DRIVE.
  
 NOTE: THE PHOTOMETRIC PLAN SUBMITTED WITH THE PERMIT
 DIFFERS THAN THE ONE SUBMITTED WITH THE SITE PLAN
 AMENDMENT.
  
 D. FENCES AND GATES - PLEASE CONSIDER USING VINYL
 COATED CHAIN LINK INSTEAD OF GALVANIZED.
  
 E. BICYCLE RACK - PROVIDE THE OVERALL HEIGHT OF BICYCLE
 RACK ABOVE GRADE AND THE FULL LENGTH DIMENSION OF THE
 BICYCLE PAD (SHEET A-109).
  
 F. SIGNAGE
  
 5) PLEASE REMEMBER THAT SINCE THE PROPOSED SITE PLAN
 MODIFIES THE EXISTING CURB CUTS ON OKEECHOBEE BOULEVARD
 AND CHILLINGWORTH DRIVE:
  
 A. AN FDOT RIGHT-OF-WAY PERMIT AND VERIFICATION OF
 SATISFACTORY COMPLETION OF THE WORK WILL BE REQUIRED
 FOR THE OKEECHOBEE BOULEVARD WORK PRIOR TO THE CITY
 ISSUING THE CERTIFICATE OF OCCUPANCY FOR THE SITE.
  
 B. A CITY RIGHT-OF-WAY PERMIT FOR CHILLINGWORTH DRIVE
 AND THE ALLEY WILL BE REQUIRED FROM THE CITY'S
 ENGINEERING SERVICES DEPARTMENT.
  
 PLEASE CONTACT ERIC SCHNEIDER @ (561) 822-1446.