2014-04-02 07:25:102010 FBC
  
 DENIED BY BUILDING
  
 1) THE STRUCTURE IS LOCATED IN A 170 MPH VULT WIND
 SPEED AND IS EXPOSURE CATEGORY C. SUBMIT TWO SETS OF
 SIGNED AND SEALED RAS 117 CALCULATIONS FOR ENHANCED
 FASTENING OF THE PERIMETER AND CORNER AREAS AS REQUIRED
 BY LIMITATION NUMBER 7 OF THE CERTAIN-TEED NOA
 NO.10-0330.02.
  
 2) A MECHANICAL SUB-PERMIT WILL BE REQUIRED TO REMOVE
 THE A/C CONDENSING UNITS AND RE-INSTALL THEM ON STANDS
 PER FBC 1509.7. THE ATTACHMENT OF THE STANDS TO THE
 ROOF WILL NEED TO BE INSPECTED BY THE MECHANICAL
 INSPECTOR BEFORE THEY ARE COVERED BY THE ROOFING
 MATERIAL.
  