Plan Review Notes For Permit 14030881 |
Permit Number |
14030881 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2014-04-16 17:04:55 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) THE WIND LOAD CALCULATIONS FOR THE LIGHTING POLES | | FROM PROFESSIONAL ENGINEER CHRISTOPHER PLY THAT ARE | | STAPLED TO THE LIGHTING PLANS DO NOT HAVE THE SITE | | ADDRESS TO TIE IT TO THIS PROJECT. FAC 61G15-23.002 | | | | 2) THE LIGHTING POLE CALCULATIONS ARE FOR A SIDE ARM | | MOUNT AND THE ONE SHOWN ON THE PLAN HAS THE LAMP | | MOUNTED DIRECTLY ON THE TOP OF THE POLE. PLEASE | | CLARIFY. CITY AMENDMENTS 107.2.1 | | | | 3) IT APPEARS THAT THE LIGHTING POLE CALCULATIONS WERE | | DONE BY A DELEGATED ENGINEER. IF THIS IS THE CASE, THEN | | THE ENGINEER OF RECORD IS REQUIRED TO REVIEW AND | | APPROVE THEM IN WRITING. FAC 61G15-30.005 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|