Date |
Text |
2014-03-28 16:48:41 | FAILED |
| |
| 1) THE SURVEY SHOWS AN FPL EASEMENT (ORB 1490, PG 461) |
| LOCATED UNDERNEATH THE NORTH HALF OF THE PROPOSED |
| BUILDING (SERVICE AND PARKING GARAGE). VERIFICATION |
| THAT THIS EASEMENT HAS BEEN ABANDONED SHALL BE PROVIDED |
| TO THE PLANNING DIVISION PRIOR TO THE CITY ISSUING |
| BUILDING PERMITS FOR STRUCTURES, INCLUDING A FOUNDATION |
| PERMIT, OVER THE EASEMENT. |
| |
| 2) THE SITE PLAN HAS NOT YET BEEN APPROVED THROUGH THE |
| MINOR AMENDMENT PROCESS BY ZONING. WHILE THE SITE PLAN |
| HAS NOT YET BEEN APPROVED, THE BUILDINGS ARE IN THE |
| SAME LOCATIONS AS SHOWN ON THE SITE PLAN. THE |
| OUTSTANDING COMMENTS, OTHER THAN THE EASEMENT COMMENT |
| ABOVE, ARE NOT ANTICIPATED TO AFFECT THE PLACEMENT OF |
| THE BUILDINGS. |
| |
| 3) A CONSTRUCTION SITE SECURITY PLAN SHALL BE SUBMITTED |
| TO OFFICER CARSILLO, CRIME PREVENTION OFFICER AND |
| APPROVED PRIOR TO THE ISSUANCE OF THE PERMIT. PLEASE |
| SEE STANDARDS BELOW: |
| |
| * KEY CONTROL FOR THE VEHICLES |
| * ALARM/CAMERA; PARTS AREA, TOOL STORAGE, KEY AREA, |
| ENTRY/EXITS, FUEL AREA, SALES AREA, CAR LOT |
| |
| PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| WORKING ENVIRONMENT. |
| B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| DEVELOPMENT. |
| C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| 500 FEET AROUND THE PERIMETER OF THE SITE. |
| |
| |
| A. PARKING LOT LIGHTING SHALL USE 20 -25 FOOT POLES. |
| FULL CUT OFF STYLE |
| B. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| LANDSCAPING SHALL BE MAINTAINED AT 3 FEET OR LESS. |
| TREES SHALL BE INSTALLED SO AS NOT TO CONFLICT WITH THE |
| LIGHTING SYSTEM. LOWER CANOPY LIMBS ON TREES SHALL BE |
| MAINTAINED AT 8 FEET OR HIGHER |
| C. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN |
| OPERATION SHALL BE PROVIDED. |
| D. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY |
| SHOULD BE AT ALL ENTRANCES WITH LIGHTING |
| E. BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND |
| PERIMETER ON ALL SIDE. |
| F. NUMERICAL ADDRESS: ILLUMINATION FOR NIGHTTIME |
| VISIBILITY IS REQUIRED. ADDRESS SHOULD BE PLACED UNDER |
| A LIGHT FIXTURE OR BE BACK LIT. BI-DIRECTIONAL |
| VISIBILITY FROM THE ROADWAY IS REQUIRED. NUMBERS OF |
| CONTRASTING COLORS SHOULD BE USED. |
| G. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY |
| HINGES AND SHALL BE REINFORCED WITH CASE HARDENED |
| STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE |
| PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH |
| THROW OR MECHANICAL INTERLOCK. |
| H. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE |
| HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK |
| CYLINDER. |
| I. EXITING DOORS SHALL BE EQUIPPED WITH 180-DEGREE |
| PEEPHOLE/ SECURITY VIEWER. |
| J. BUILDING ARCHITECTURE SHALL ALLOW FOR ENHANCED |
| NATURAL SURVEILLANCE OF ALL PARKING LOTS AND PROVIDE A |
| SENSE OF SECURITY TO PATRONS AND VISITORS. |
| K. DRIVE-THRU LANES SHALL HAVE ONE WAY SIGNAGE STATING |
| SAME. |
| L. CROSSWALKS SHALL BE RAISED AND DELINEATED BY USING |
| CONTRASTING PAVER BLOCKS AS OPPOSED TO SURFACE |
| STRIPING. |
| M. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT |
| TELEVISION (CCTV) AND ALARM SYSTEMS. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
2014-03-28 09:54:47 | 3/28/14 |