2014-06-06 17:42:45 | BUILDING PLAN REVIEW |
| PERMIT: 14030562 |
| ADD: 1875 PALM BCH LAKES # A09 |
| CONT: TO BE DETERMINED |
| TEL: (561)373-3902 / KARI |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2ND REVIEW |
| DATE: FRIDAY JUNE 06/2014 |
| ACTION: DENIED |
| |
| 1) COMPLIED. |
| |
| 2) PB OUTLET MALLS: |
| A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND |
| NOTARIZED. |
| |
| 3A) COMPLIED. |
| |
| 3B) NOTE TO DESIGNER!!!: CHAPTER 553.80(2)(B) FLORIDA |
| STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A |
| FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE |
| REJECTED THREE OR MORE TIMES FOR REPEATED FAILURE TO |
| CORRECT A CODE VIOLATION. |
| |
| 2ND REQUEST!!!THE PLANS, LIFE SAFETY SHEET A1.0 ARE |
| INDICATING THEY ARE TAKING AREA INCREASES FOR FIRE |
| SPRINKLERS, THE INDEX AND PLANS FAIL TO CONTAIN FIRE |
| SPRINKLER & FIRE ALARM PLANS WITHIN THIS SET. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| (5) . FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: |
| SCHEMATIC FIRE SPRINKLERSFIRE SPRINKLER PLANS ARE A |
| MUST, OVER 12,000 SQ FT. SHEET A1.0 INDICATE A AREA |
| INCREASE OF 300% WITH |
| FIRE SPRINKLERS, THERE ARE NO FIRE SPRINKLER PLANS |
| LISTED IN THE INDEX NOR IS THERE A SEPARATE SET OF FIRE |
| SPRINKLER PLANS SUBMITTED WITH THE 2ND SUBMITTAL. |
| |
| SECTION NOT MET: 2010 FBC-B F] 903.2.7 GROUP M. AN |
| AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED THROUGHOUT |
| BUILDINGS CONTAINING A GROUP M OCCUPANCY WHERE ONE OF |
| THE FOLLOWING CONDITIONS EXISTS: 1. A GROUP M FIRE AREA |
| EXCEEDS 12,000 SQUARE FEET (1115 M2). |
| |
| 3C) COMPLIED. |
| |
| 4) 2ND REQUEST, BUILDING EVALUATION IS STILL LOW. THE |
| ICC TABLES PUT THE BUILDING TYPE IIB AT $115.47 SQ FT. |
| THE SHELL' |
| ROOF & FIRE SPRINKLERS TOTAL COST COMES TO $44.00 A |
| SQUARE FOOT OR THE TENANT BUILD OUT WITH THE FIRE |
| SPRINKLERS FOR THE TENANT BUILD OUT INCLUDED AT $71.00 |
| A SQUARE FOOT. |
| THE TENANT BUILD OUT VALUE IS LOW AT $18.64 DOLLARS / |
| SQ FT. W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF |
| PERMIT FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, |
| MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS |
| REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID |
| AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE |
| ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. |
| |
| 108.3* BUILDING PERMIT VALUATION. |
| IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| 5-7) COMPLIED. |
| |
| 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |