2014-04-14 15:47:34BUILDING PLAN REVIEW
 PERMIT: 14030562
 ADD: 1875 PALM BCH LAKES # A09
 CONT: TO BE DETERMINED
 TEL: (561)373-3902 / KARI
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: MONDAY APRIL 14/ 2014
 ACTION: DENIED
  
 1) THE PLANS DO NOT HAVE THE STAMP OF APPROVAL OR
 LETTER FROM NEW ENGLAND DEVELOPMENT PALM BEACH OUTLETS
 SKYE GROUP TENANT COORDINATOR THAT THE PLANS AAND
 DESIGN ARE APPROVED.
  
 2) PB OUTLET MALLS:
 A LETTER FROM THE QUALIFIER OF BOTH THE SHELL
 CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT
 CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT
 PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT
 CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK
 HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY
 WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE
 DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND
 NOTARIZED.
  
 3A) THE PLANS, LIFE SAFETY SHEET A1.0 DO NOT PROVIDE
 THE MINIMUM TYPE OF CONSTRUCTION, SHELL PERMIT IS TYPE
 IIB. 2010 FBC-B TABLE 503.
  
 3B) THE PLANS, LIFE SAFETY SHEET A1.0 ARE INDICATING
 THEY ARE TAKING AREA INCREASES FOR FIRE SPRINKLERS, THE
 INDEX AND PLANS FAIL TO CONTAIN FIRE SPRINKLER & FIRE
 ALARM PLANS WITHIN THIS SET.
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 (5) . FIRE SUPPRESSION SYSTEMS SHALL INCLUDE:
 EARLY WARNING SMOKE EVACUATION SYSTEMS
 SCHEMATIC FIRE SPRINKLERS
 STANDPIPES
 PRE-ENGINEERED SYSTEMS
 RISER DIAGRAM
  
 3C) THE LIFE SAFETY PLANS DO NOT PROVIDE ANY DETAILS
 FOR COMPLIANCE WITH :
 2010 FBC- ACCESSIBILITY CODE.
 904.3 CHECK-OUT AISLES.
 CHECK-OUT AISLES SHALL COMPLY WITH 904.3.
 904.3.1 AISLE.
 AISLES SHALL COMPLY WITH 403.
 904.3.2 COUNTER.
 THE COUNTER SURFACE HEIGHT SHALL BE 38 INCHES (965 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. THE TOP OF
 THE COUNTER EDGE PROTECTION SHALL BE 2 INCHES (51 MM)
 MAXIMUM ABOVE THE TOP OF THE COUNTER SURFACE ON THE
 AISLE SIDE OF THE CHECK-OUT COUNTER
  
 904.4 SALES AND SERVICE COUNTERS.
 SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH
 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE
 COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR
 SERVICE COUNTER TOP.
  
 4) THE TENANT BUILD OUT VALUE IS LOW AT $18.64 DOLLARS
 / SQ FT. W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF
 PERMIT FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS,
 MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS
 REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID
 AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE
 ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 5) SHEET A2.2 INDICATES THE USE OF A X-RAY MACHINE IN
 ROOM 128 THERE DOES NOT APPEAR TO BE ANY SHIELDING OF
 WALLS NOR IS THERE A DOOR. FBC-B 435.5.1. SHIELDING.
  
 6) SHEET A5.0 CURB DETAILS PLEASE SHOW COMPLIANCE WITH
 FBC-B 1509.7 MECHANICAL UNITS. ROOF MOUNTED MECHANICAL
 UNITS SHALL BE MOUNTED ON CURBS RAISED A MINIMUM OF 8
 INCHES (203 MM) ABOVE THE ROOF SURFACE, OR WHERE
 ROOFING MATERIALS EXTEND BENEATH THE UNIT,
  
 7) ALL ARCHITECTURAL SHEETS ARE COPIES OF THE ORIGINAL
 SIGNATURE, ALL SIGNATURES ARE IDENTICAL AND PIXOLATED.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G16.003 ARCHITECTS
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  