2014-04-14 15:47:34 | BUILDING PLAN REVIEW |
| PERMIT: 14030562 |
| ADD: 1875 PALM BCH LAKES # A09 |
| CONT: TO BE DETERMINED |
| TEL: (561)373-3902 / KARI |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 1ST REVIEW |
| DATE: MONDAY APRIL 14/ 2014 |
| ACTION: DENIED |
| |
| 1) THE PLANS DO NOT HAVE THE STAMP OF APPROVAL OR |
| LETTER FROM NEW ENGLAND DEVELOPMENT PALM BEACH OUTLETS |
| SKYE GROUP TENANT COORDINATOR THAT THE PLANS AAND |
| DESIGN ARE APPROVED. |
| |
| 2) PB OUTLET MALLS: |
| A LETTER FROM THE QUALIFIER OF BOTH THE SHELL |
| CONTRACTOR (EMJ CORPORATION) AND TENANT BUILD-OUT |
| CONTRACTOR MUST BE PROVIDED BEFORE TENANT BUILD-OUT |
| PERMIT CAN BE ISSUED, IF THE TENANT BUILD-OUT |
| CONTRACTOR WISHES TO START WORK BEFORE THE SHELL WORK |
| HAS RECEIVED A CERTIFICATE OF COMPLETION, AGREEING THEY |
| WILL WORK TOGETHER TO ACHIEVE CODE COMPLIANCE. THESE |
| DOCUMENTS WILL NEED TO BE SIGNED BY THE QUALIFIER AND |
| NOTARIZED. |
| |
| 3A) THE PLANS, LIFE SAFETY SHEET A1.0 DO NOT PROVIDE |
| THE MINIMUM TYPE OF CONSTRUCTION, SHELL PERMIT IS TYPE |
| IIB. 2010 FBC-B TABLE 503. |
| |
| 3B) THE PLANS, LIFE SAFETY SHEET A1.0 ARE INDICATING |
| THEY ARE TAKING AREA INCREASES FOR FIRE SPRINKLERS, THE |
| INDEX AND PLANS FAIL TO CONTAIN FIRE SPRINKLER & FIRE |
| ALARM PLANS WITHIN THIS SET. |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| (5) . FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: |
| EARLY WARNING SMOKE EVACUATION SYSTEMS |
| SCHEMATIC FIRE SPRINKLERS |
| STANDPIPES |
| PRE-ENGINEERED SYSTEMS |
| RISER DIAGRAM |
| |
| 3C) THE LIFE SAFETY PLANS DO NOT PROVIDE ANY DETAILS |
| FOR COMPLIANCE WITH : |
| 2010 FBC- ACCESSIBILITY CODE. |
| 904.3 CHECK-OUT AISLES. |
| CHECK-OUT AISLES SHALL COMPLY WITH 904.3. |
| 904.3.1 AISLE. |
| AISLES SHALL COMPLY WITH 403. |
| 904.3.2 COUNTER. |
| THE COUNTER SURFACE HEIGHT SHALL BE 38 INCHES (965 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. THE TOP OF |
| THE COUNTER EDGE PROTECTION SHALL BE 2 INCHES (51 MM) |
| MAXIMUM ABOVE THE TOP OF THE COUNTER SURFACE ON THE |
| AISLE SIDE OF THE CHECK-OUT COUNTER |
| |
| 904.4 SALES AND SERVICE COUNTERS. |
| SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH |
| 904.4.1 OR 904.4.2. THE ACCESSIBLE PORTION OF THE |
| COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR |
| SERVICE COUNTER TOP. |
| |
| 4) THE TENANT BUILD OUT VALUE IS LOW AT $18.64 DOLLARS |
| / SQ FT. W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF |
| PERMIT FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, |
| MECHANICAL, AND PLUMBING SYSTEMS OR ALTERATIONS |
| REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID |
| AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE |
| ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. |
| |
| 108.3* BUILDING PERMIT VALUATION. |
| IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED |
| DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| 5) SHEET A2.2 INDICATES THE USE OF A X-RAY MACHINE IN |
| ROOM 128 THERE DOES NOT APPEAR TO BE ANY SHIELDING OF |
| WALLS NOR IS THERE A DOOR. FBC-B 435.5.1. SHIELDING. |
| |
| 6) SHEET A5.0 CURB DETAILS PLEASE SHOW COMPLIANCE WITH |
| FBC-B 1509.7 MECHANICAL UNITS. ROOF MOUNTED MECHANICAL |
| UNITS SHALL BE MOUNTED ON CURBS RAISED A MINIMUM OF 8 |
| INCHES (203 MM) ABOVE THE ROOF SURFACE, OR WHERE |
| ROOFING MATERIALS EXTEND BENEATH THE UNIT, |
| |
| 7) ALL ARCHITECTURAL SHEETS ARE COPIES OF THE ORIGINAL |
| SIGNATURE, ALL SIGNATURES ARE IDENTICAL AND PIXOLATED. |
| PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| FL ADMIN CODE 61G16.003 ARCHITECTS |
| |
| 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |