2014-03-22 11:17:51 
 BUILDING PLAN REVIEW
 REVISION: 14030431
 PERMIT: 13100374
 ADD: 2921 N AUSTRALIAN AVE.
 CONT: DB K INDUSTRIES
 TEL: (561)827-4920 JAMES STINSON
  
 1ST REVIEW
 DATE: SAT. MARCH 22/ 2014
 ACTION: DENIED
  
 1) SHOP DRAWING FOR HANDRAIL DOES NOT INDICATE WHERE
 THE LANDING IS LOCATED. IT APPEARS EITHER A SECTION IS
 INCORPORATED INTO THE ELEVATION DRAWING SHOWING THE
 BOTTOM POST AND SLAB BEING CORED OR ANOTHER RISER,
 PLEASE IDENTIFY WHAT IS BEING ILLUSTRATED.
  
 2) THE SHOP DRAWING FOR A HANDRAIL WILL NEED TO COMPLY
 WITH THE 2010 FL ACCESSIBILITY CODE 504.6 HANDRAILS.
 STAIRS SHALL HAVE HANDRAILS COMPLYING WITH 505.
 505.2 WHERE REQUIRED. HANDRAILS SHALL BE PROVIDED ON
 BOTH SIDES OF STAIRS AND RAMPS.
  
 2A) 505.10 HANDRAIL EXTENSIONS. HANDRAIL GRIPPING
 SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION
 OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH
 505.10.
 2B)
 05.10.2 TOP EXTENSION AT STAIRS. AT THE TOP OF A STAIR
 FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE
 LANDING FOR 12 INCHES (305 MM) MINIMUM BEGINNING
 DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL
 RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR
 SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT
 STAIR FLIGHT.
  
 2C) 505.10.3 BOTTOM EXTENSION AT STAIRS. AT THE BOTTOM
 OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE
 OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE AT LEAST
 EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING.
 EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE LANDING
 SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN
 ADJACENT STAIR FLIGHT.
  
 3) PLEASE NOTE: THIS BUILDING IS BEING CONVERTED INTO A
 FUNERAL HOME. THE OWNER HAS NOT APPLIED FOR A CHANGE OF
 OCCUPANCY PERMIT. NOR WILL A CHANGE OF OCCUPANCY PERMIT
 BE GRANTED. THIS IS A ZONING ISSUE ANGELLIA JONES VANN
 MADE THE OWNER AWARE OF LAST YEAR.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  