Date |
Text |
2014-03-10 16:50:43 | 2010 FBC |
| |
| DENIED BY BUILDING |
| |
| 1) THE STRUCTURE IS LOCATED IN A 170 MPH VULT WIND |
| SPEED AND THE EXPOSURE CATEGORY IS C. THE ROOFING |
| SYSTEM ON PAGE 31 OF NOA NUMBER 13-0204.03 HAS A |
| MAXIMUM DESIGN PRESSURE OF -60 PSF, WHICH IS TOO LOW |
| FOR THE CORNER AND PERMITER AREAS OF THE ROOF. GENERAL |
| LIMITATION #7 ON SHEET 32 REQUIRES SIGNED AND SEALED |
| RAS117 CALCULATIONS FOR ENHANCED FASTENING OF THE BASE |
| SHEET. SUBMIT TWO COPIES OF RAS 117 CALCULATIONS FOR |
| THE BASE SHEET FASTENING. |
| |
| 2) AN AFFIDAVIT SIGNED BY THE QUALIFER AND NOTARIZED |
| WAS SUBMITTED INDICATING THAT THE WORK HAS BEEN |
| COMPLETED AND PERSONALLY INSPECTED BY THE QUALIFER. |
| SECTION 105.1 OF THE CITY OF WESTPALM BEACH REQUIRES |
| CONTRACTOR'S TO APPLY FOR AND OBTAIN A PERMIT BEFORE |
| THE WORK IS STARTED. CITY AMENDMENT 109.4 STATES THAT |
| ANY PERSON COMMENCING WORK ON A BUILDING WITHOUT FIRST |
| OBTAINING THE NECESSARY IS SUBJECT TO A PENALTY FEE IN |
| ADDITION TO THE REQUIRED PERMIT FEES. THE PENALTY FEE |
| HAS BEEN ADDED TO THIS PERMIT. |
| |
| 3) THE CITY OF WEST PALM BEACH CONSTRUCTION SERVICES |
| DIVISION DOES NOT ACCEPT AFFIDAVITS IN LIEU OF THE |
| REQUIRED INSPECTIONS. AFTER THE PERMIT HAS BEEN ISSUED, |
| THE REQUIRED INSPECTIONS WILL BE MADE BY ONE OF THE |
| CONSTRUCTION SERVICE' S BUILDING INSPECTORS. CITY |
| AMENDMENTS 110.1 |
| |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| [email protected] |