2014-05-23 16:35:21 | 1. COLUMNS ON GARAGE VEHICULAR ACEESS ENCROACH INTO THE |
| SETBACK. |
| 2. GROSS AREA INDICATED ON SHEET SD-1 IS 192,065SF |
| WHILE SP-1.1 INDICATED 272,963SF. PLEASE CLARIFY |
| DIFFERENCE. SITE PLAN APPROVAL DRAWINGS INDICATE |
| 274,976SF. |
| 3.DRAWINGS SEEM TO INDICATE AN ADDITIONAL UNIT ADDED ON |
| THE TOP FLOOR ON THE WEST SIDE OF THE PARKING GARAGE. |
| PLEASE EXPLAIN IF THAT IS THE CASE, AND INDICATE THE |
| INCREASE IN SQUARE FOOTAGE. |
| 4.PLEASE INCLUDE A COMPLETE GROSS BUILDING AREA, AND |
| OPEN SPACE REQUIREMENT CALCULATION TABLE AS INCLUDED IN |
| THE SITE PLAN APPROVAL DRAWINGS. |
| 5. PLEASE INDICATE THE MECHANICAL SCREENING FOR ALL |
| ROOF TOP EQUIPMENT. PARAPET WALL SHALL BE AS HIGH AS |
| THE MECHANICAL EQUIPMENT. |
| 6. PLEASE SPECIFY THAT THE TREE GRATE SHALL MATCH |
| EXISTING ON OLIVE AND DIXIE AVENUE. |
| 7. STREET LIGHT SHALL MATCH EXISTING ON OLIVE AND DIXIE |
| HWAY. |
| 8. BIKE RACK SPECIFIED ON DETAILS INCLUDES TWO ANCHORS. |
| PLEASE INDICATE THE TWO ANCHORS IN THE OVERALL DRAWINGS |
| OR INCLUDE A SPECIFIC INSTALLATION DETAIL IDENTIFYING |
| MINIMUM DISTANCES TO COMPLY WITH BIKE RACK INSTALLATION |
| STANDARDS. |
| 9. ARE THE BIKE RACKS PROPOSED INSIDE THE PARKING |
| GARAGE THE SAME MODEL THAN THE ONES OUTSIDE BY THE |
| PLAZA? PLEASE SPECIFY IF DIFERENT. |
| 10. IT SEEMS THERE IS A UTILITY LINE RUNNING UNDER THE |
| MIDDLE OF THE TREE GRATES ON OLIVE AVE. PLEASE CONFIRM |
| THAT IS NOT THE CASE OR RELOCATE. |
| 11. SWITCH BOXES SHALL INCLUDE A SCREEN FILM IF |
| LANDSCPE IS NOT POSSIBLE FOR SCREENING. |
| 12. SIDEWALK ON SOUTH SIDE OF EUCALYPTUS SHALL BE |
| COMPLETED FROM THE PHASE I TO DIXIE HWAY, OR AT LEAST |
| CONNECTED WITH THE EXISTING SIDEWALK TO ALLOW |
| PEDESTRIAN TRAFFIC ALONG THE ENTIRE FRONTAGE. |
| 13. HAVE THE TOTAL NUMBER OF TREES BEING MODIFIED SINCE |
| THE SITE PLAN APPROVAL? OVERALL DRAWIGNS DO NOT SEEM TO |
| HAVE THE SAME NUMBER THAN THE DETAIL DRAWINGS. |
| 14. STRUCTURAL SOITL SHALL BE SPECIFIED UNDER THE |
| SIDEWALK 10' AROUND THE TREE TRUNK. PHOTOS OF THE |
| STRUCTURAL SOIL INSTALLATION SHALL BE SUBMITTED AS PART |
| OF THE CO PROCESS. |
| 15. IF THE ROOF TOP IS COUNTED AS PART OF THE PRIVATE |
| OPEN SPACE, PLEASE PROVIDE INFORMATION TO CONFIRM |
| COMPLIANCE WITH LANDSCAPE ROOF TOP REQUIREMENTS. |
| 16. AS THE PUBLIC OPEN SPACE IS PROPOSED ALL UNDER THE |
| PHASE I, IT SHALL BE BUILT IN ITS ENTIRETY DURING THIS |
| PHASE. |
| 17. MAIN BUILDING ENTRANCE WAS MODIFIED FROM THE DIXIE |
| FRONTAGE TO THE 6TH STREET FRONTAGE. HOWEVER, BUILDING |
| DESIGN STILL SEEMS TO DIRECT PEDESTRIANS TO THE DIXIE |
| ENTRANCE DUE TO THE ARCHITECTURAL FEATURE ON THE |
| BUILDING. SOME ADDITIONAL FEATURE SHALL BE ADDED UNDER |
| THAT COVERED ENTRANCE (FOUNTAIN?) AND THE NEW MAIN |
| ENTRANCE SHALL BE ENHANCED TO CREATE A NEW ENTRY |
| FEATURE ON THE NEW LOCATION. |
| 18. WHAT ARE THE NEW VERTICAL LINES SHOWN ON THE 6TH |
| STREET ELEVATION WEST OF THE STAIR AND EAST OF THE |
| PARKIGN ENTRANCE? |
| 19. IS THERE ANY CHANGE ON THE SIDEWALK ELEVATION EAST |
| AND WEST OF THE PARKING ENTRANCE? |
| 20. PLEASE INCLUDE DIMENSIONS FOR ALL PARKING STALLS |
| WITHIN THE GARAGE. |
| 21. BALCONIES CANNOT ENCROACH MORE THAN 5 FEET INTO |
| MINIMUM SETBACK. PLEASE CONFIRM COMPLIANCE. |
| 22. BAND THAT SEPARATED BASE FROM MIDDLE AT THE N SIDE |
| OF THE OLIVE ELEVATION IS MISSING SHEET A-3.1.1 |
| 23. NEW DOORS ON SIDES OF LOADING ARE NOT ACCURATELY |
| REFLECTED ON ELEVATION. FACADE SHALL BE ADJUSTED TO |
| REFLECT THE NEW ELEMENTS. |
| 24. BUILDING NAME IS NOT ALLOWED AS A MONUMENT SIGN, IT |
| SHALL BE LOCATED ON THE BUILDING FACADE. |
| FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| APONTE AT 561-822-1439. |
| |