2014-07-31 18:26:452010 FBC
  
 DENIED BY BUILDING
  
 1) ONLY ONE TRUSS PLACEMENT PLAN FOR THE MODEL 'F'
 GABLE WAS SUBMITTED. A MINIMUM OF TWO SETS IS REQUIRED.
 CITY AMENDMENTS 107.1
  
 2) NO TRUSS PLACEMENT PLANS FOR THE MODEL 'F' HIP (
 ALTERNATE ROOF FRAMING PLAN) OR TRUSS DRAWINGS WERE
 SUBMITTED. SUBMIT TWO SETS OF SIGNED AND SEALED TRUSS
 PLACEMENT PLANS AND TRUSS DRAWINGS AS REQUIRED BY CITY
 AMENDMENTS 107.1 AND DCA RULE 9N-3.
  
 3) THE TRUSS PLACEMENT PLANS AND DRAWINGS FOR THE MODEL
 'F' HIP ( ALTERNATE ROOF FRAMING PLAN) FROM THE
 DELEGATED ENGINEER ARE REQUIRED TO BE REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD. CITY AMENDMENTS
 107.3.4.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]