Date |
Text |
2014-03-28 11:37:53 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6724 |
| |
| COMMENTS FROM FIRST REVIEW: |
| |
| 1. PROVIDE A PLAN WHICH SHOWS ROOM DESIGNATIONS FOR |
| ROOMS ADJACENT TO THE PORCH AND OPENINGS INTO THE |
| PROPOSED ENCLOSED PORCH, FBC 107, FBC 2010 RESIDENTIAL |
| 310. INCLUDE A ROOM DESIGNATION (USE) FOR PROPOSED |
| AREA. |
| |
| PLAN PROVIDED IS NOT LEGIBLE. PORCH DOES NOT APPEAR TO |
| BE SHOWN. PLEASE PROVIDE A LEGIBLE PLAN. CLEARLY SHOW |
| SCOPE. IT IS SUGGESTED THAT "EXISTING" (MEANING BEFORE |
| WORK WAS DONE WITHOUT PERMIT) AND "PROPOSED" (WORK TO |
| BE COVERED UNDER THIS PERMIT) FLOOR PLANS ARE |
| SUGGESTED. |
| |
| BASED ON INFORMATION PROVIDED, IT APPEARS THAT BEDROOM |
| PREVIOUSLY HAD A SLIDING GLASS DOOR OPENING INTO A |
| SCREEN PORCH AS THE EMERGENCY MEANS OF ESCAPE. BASED ON |
| PERMIT APPLICATION DESCRIPTION, IT APPEARS THAT THE |
| EMERGENCY MEANS OF ESCAPE HAS BEEN ELIMINATED AS THE |
| PORCH IS NO LONGER OPEN. THIS IS NOT PERMITTED UNLESS |
| THE BUILDING IS FULLY SPRINKLERED. |
| |
| 2. IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY. NOT |
| ENOUGH INFORMATION PROVIDED TO DETERMINE AT THIS TIME. |
| |
| 3. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R |
| 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS |
| ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE |
| (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM |
| /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF) |
| |
| |