2015-01-06 08:19:37 | BUILDING PLAN REVIEW |
| PERMIT: 14020179 |
| PCN: 00-42-43-24-00-000-5251 |
| P. B. C. TO BE ANNEXED |
| ADD: 2132 INDIAN RD |
| CONT: CREATIVE CONTRACTING GROUP |
| TEL: (561)333-1445 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| NOTICE:!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! |
| !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! |
| !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! |
| CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A |
| LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE |
| FEE FOR |
| PLAN REVIEW, IF PLANS ARE REJECTED (3) OR MORE TIMES |
| FOR REPEATED FAILURE TO CORRECT A CODE VIOLATION. |
| |
| 5TH REVIEW |
| DATE: TUES. JAN. 06/ 2015 |
| ACTION: DENIED |
| |
| 1) ADDRESS/ COMPLIED. |
| |
| 2) COMPLIED. |
| |
| 3) COMPLIED. SOILS REPORT. |
| |
| 4) COMPLIED. WIND EXPOSURE. |
| |
| 5) 5TH REQUEST. 2010 FBC-B 1609.1.2 PROTECTION OF |
| OPENINGS, 1609.6.4.41 COMPONENTS & CLADDING |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| |
| (31)(C) WALL PANELS. |
| |
| (31)(D) ROOFING PANELS. NOTE A SINGLE COPY OF A ROOFING |
| NOA 12-0716.16 WAS SUBMITTED, WHY WOULD A MODIFIED |
| BITUMEN ROOFING PRODUCT BE PUT ON A STRUCTURAL STEEL |
| PANEL ROOF. |
| |
| 6A) 5TH REQUEST. THE NEW STEEL BUILDING PLANS BY LUDWIG |
| WILL NEED TO PROVIDE PRODUCT APPROVALS FOR THE WALL |
| PANELS AND ROOFING SYSTEMS. 107.3.4.1 PRODUCT |
| APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE |
| DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN |
| WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| |
| 6B) 5TH REQUEST. THE LUDWIG STEEL BUILDING PLANS ARE ON |
| 8 1/2 X 11 SHEETS OF PAPER, THEY DO NOT MEET THE |
| REQUIRED SIZE REQUIREMENTS FOR RECORD RETENTION. |
| 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS |
| SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON |
| SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. |
| THE BUILDING OFFICIAL MAY ESTABLISH THROUGH |
| DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND |
| SPECIFICATIONS, IN |
| ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION |
| PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM |
| SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED |
| TO RECORDS MANAGEMENT. |
| |
| 6C) 5TH REQUEST. WITH THE REDUCED SIZE OF THE ENGINEERS |
| SEAL THE PLANS DO NNOT MEET THE SEAL REQUIREMETS. |
| 61G15-23.001 SEALS ACCEPTABLE TO THE BOARD. SAID SEAL |
| SHALL BE A MINIMUM OF 1 7/8 INCHES IN DIAMETER, TO SAY |
| LICENSE NOT CERTIFICATE. ALL ENGINEERS MUST BE |
| UTILIZING SAID SEAL NO LATER THAN JANUARY 1, 2006. |
| |
| 7) 5TH REQUEST. SHEET S-6 & S-10 BOTH INDICATE THE USE |
| OF HELICAL PILES PER COLUMN, IS THERE A SUPPORTING |
| SOILS REPORT/ 2010 FBC-B 1803.5.2 QUESTIONABLE SOIL. |
| WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY |
| OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE |
| SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE |
| BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A |
| GEOTECHNICAL INVESTIGATION BE CONDUCTED. NO PRODUCT |
| INFORMATION FOR THE HELICAL PIERS SHEET S-10 DETAIL # 1 |
| INDICATES THE USE OF HELICAL PILE WHERE AS DETAIL 2 & 3 |
| BOTH LOOK LIKE AUGER PILE. 107.2.1.3 ADDITIONAL |
| INFORMATION IS REQUIRED. NO COMMENT RESPONCE FOR THIS |
| REQUEST. |
| |
| 8) 5TH REQUEST. BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. |
| THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 9) 5 TH REQUEST. WHEN RESUBMITTING PLANS PLEASE |
| INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |