2014-05-02 12:16:57 | BUILDING PLAN REVIEW |
| PERMIT: 14020179 |
| PCN: 00-42-43-24-00-000-5251 |
| P. B. C. TO BE ANNEXED |
| ADD: 2132 INDIAN RD |
| CONT: CREATIVE CONTRACTING GROUP |
| TEL: (561)333-1445 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. FEB. 25/ 2014 |
| ACTION: DENIED |
| |
| 1) ADDRESS/ COMPLIED. |
| |
| 2) 2ND REQUEST. THIS SITE IS BEING ANNEXED INTO THE |
| CITY, IT IS LOCATED WITHIN AN A8 FLOOD ZONE. THE |
| MINIMUM BASE FLOOD ELEVATION IS 16.00 FT NGVD THE CITY |
| OF WEST PALM BEACH REQUIRES AN ADDITIONAL 6 INCHES TO |
| THE BASE FLOOD OR A FINISH FLOOR OF 16.5 FT NGVD. |
| THE SURVEY INDICATES A FINISH FLOOR OF 16.53 NGVD. |
| |
| 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| 107.3.5.1 COMMERCIAL BUILDINGS: |
| 107.3.5.1.1. BUILDING |
| 107.3.5.1.1.SITE REQUIREMENTS: FLOOD HAZARD AREAS, |
| FLOOD ZONES, AND DESIGN FLOOD ELEVATIONS PROVIDE WHAT |
| THE EXISTING FINISH FLOOR ELEVATION IS IN NDVD. |
| |
| 2.2 COMPLIED. |
| SHEET S7 INDICATES THE OCCUPANCY AS A F1 LIGHT AUTO |
| REPAIR/ USED TIRE SALE, PLEASE REVIEW 2010 FBC-B 406.6 |
| REPAIR GARAGES ARE SPECIAL OCCUPANCIES LISTED AS A S2. |
| |
| 2.3)COMPLIED. |
| OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: |
| SPECIFIC OCCUPANCY REQUIREMENTS |
| |
| 2.4 2ND REQUEST. STRUCTURAL REQUIREMENTS SHALL INCLUDE: |
| SOIL CONDITIONS/ANALYSIS- MISSING |
| BUILDING ENVELOPE: PRODUCT APPROVALS SEE COMMENT 6 |
| BELOW. |
| FOUNDATION MISSING ELEVATION CERTIFICATE. |
| FLOOD REQUIREMENTS IN ACCORDANCE WITH SECTION 1612, |
| INCLUDING LOWEST FLOOR ELEVATIONS, ENCLOSURES, FLOOD |
| DAMAGE-RESISTANT MATERIALS |
| |
| |
| 3) PLEASE PROVIDE A CURRENT SURVEY SIGNED AND SEALED |
| (2) ORIGINALS & FLOOD ZONE CERTIFICATES, THIS STRUCTURE |
| IS LOCATED IN A A8 FLOOD ZONE WITH A REQUIRED 16.00 |
| ELE. NGVD. THE CITY MUNI CODE FLOOD PREVENTION AND |
| CONTROL REQUIRES AN ADDITIONAL 6 INCH FREE BOARD FOR |
| RESIDENTIAL AND FOR COMMERCIAL FLOOD PROOFING FOR THE |
| SAME 6 INCHES PLUS A ADDITIONAL 6 INCHES IF FLOOD |
| PROOFING AND THE FLOOR NOT BEING ABOVE 16.5 FT. NGVD. |
| FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES |
| SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD |
| ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED. |
| PLEASE REVIEW CITY ORDINANCE FOR THE CITY REQUIREMENTS |
| REQUIRE AN ADDITIONAL 6 INCHES OF ELEVATION |
| |
| DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE |
| REQUIRED (3) DIFFERENT FLOOD ZONE CERTIFICATES |
| REQUIRED: |
| (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE |
| PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR |
| HEIGHT. |
| (2) ONCE THE FIRST FLOOR SLAB IS POURED THE 2ND |
| ELEVATION CERTIFICATE IS REQUIRED |
| (3) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY |
| OR A CERTIFICATE OF COMPLETION THE 3RD FLOOD ZONE |
| CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR |
| ATTENDANT |
| A/C PADS OR OTHER SLABS FOR GENERATORS |
| |
| FEMA FORM OMB NO. 1660-0008 EXPIRES: |
| JULY 31,2015 |
| |
| FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR |
| USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. |
| |
| 4) COMPLIED EXPOSURE C. |
| |
| 5) SEMI-COMPLIED. SEE COMMENT # 6 BELOW. 2010 FBC |
| 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 6) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| 1609.6.4.41 COMPONENTS & CLADDING |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| |
| (31)(A) EXTERIOR DOORS. COMPLIED. |
| |
| (31)(C) WALL LOUVERS- REQUIRE PRODUCT APPROVALS 1ST |
| REVIEW! |
| |
| (D) 2ND REQUEST, NOA 12-0716.16 ROOFING PRODUCTS AND |
| ASSEMBLIES FOR FLAT ROOFS PLEASE IDENTIFY SUB-SYSTEMS |
| AND ASSOCIATED PRESSURES, REVIEW LIMITATIONS FOR THIS |
| APPROVAL. |
| NO SUB-SYSTEM WAS IDENTIED, DEPENDING ON WHICH |
| SUB-SYSTEM IS IDENTIFIED. ZONES 2 & 3, MAY REQUIRE |
| ENHANCED FASTENING SEE LIMITATION 7 & 9. |
| |
| 7) 2ND REQUEST, OWNERS SOILS REPORT PROVIDED. SHEET S-6 |
| & S-10 BOTH INDICATE THE USE OF HELICAL PILES PER |
| COLUMN, IS THERE A SUPPORTING SOILS REPORT/ 2010 FBC-B |
| 1803.5.2 QUESTIONABLE SOIL. |
| WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY |
| OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE |
| SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE |
| BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A |
| GEOTECHNICAL INVESTIGATION BE CONDUCTED. |
| |
| 8) 2ND REQUEST. NO PRODUCT INFORMATION FOR THE HELICAL |
| PIERS SHEET S-10 DETAIL # 1 INDICATES THE USE OF |
| HELICAL PILE WHERE AS DETAIL 2 & 3 OTH LOOK LIKE AUGER |
| PILE? 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. |
| |
| 9) COMPLIED. |
| |
| 10) 406.6.1 GENERAL. |
| REPAIR GARAGES SHALL BE CONSTRUCTED IN ACCORDANCE WITH |
| THE FLORIDA FIRE PREVENTION CODE AND SECTIONS 406.6.1 |
| THROUGH 406.6.6. THIS OCCUPANCY SHALL NOT INCLUDE MOTOR |
| FUEL-DISPENSING FACILITIES, AS REGULATED IN SECTION |
| 406.5. |
| |
| 11) NOT USED. |
| |
| 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |