2014-03-14 11:30:59RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. SEC. 109.3 CITY AMENDMENTS TO FBC. VALUATION NEEDS
 TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD
 AND PROFIT, AND DESIGN PROFESSIONAL FEES. VALUATION WAS
 UPDATED TO $25,000. PERMIT FEE BALANCE IS $762.74.
  
 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 101.4.3 OF 2010 FBC-ENERGY CONSERVATION. PLEASE MAKE
 SURE FORM IS COMPLETELY FILLED AND SIGNED AND DATED BY
 EVERYBODY AT BOTTOM OF FORM.
  
 3- PLANS SUBMITTED HAVE A NOTE AT THE BOTTOM OF THE
 SHEET SPECIFYING THAT THIS DRAWINGS ARE NOT FOR
 CONSTRUCTION. REVISE NOTE AS REQUIRED. NEED TO PROVIDE
 PLANS THAT ARE DESIGNED FOR PERMITTING AND
 CONSTRUCTION. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 4- PLANS TO SPECIFY ALL THE INFORMATION AS REQUIRED BY
 SEC. 107.3.5.3 OF CITY AMENDMENTS TO FBC:
 A) CURRENT BUILDING CODE.
  
 B) DESIGN CRITERIA: ULTIMATE WIND SPEED VULT AND THE
 NOMINAL WIND SPEED VASD AS REQUIRED BY SEC. R301 OF
 2010 FBC-RESIDENTIAL.
  
 C) ALL DESIGN LOADS: LIVE AND DEAD LOADS. SEC. R301.
  
 D) ALL WINDOWS AND DOORS DESIGN PRESSURES. SEC. R301.
  
 E) BUILDING EXPOSURE. SEC. R301.
  
 F) FOUNDATION PLAN. AND, SPECIFY FOOTING SIZE. NOTE:
 KEEP IN MIND THAT FOOTING HAS TO BE 12" BELOW GRADE AND
 NEED 6" CLEARANCE FROM FINISH GRADE FOR TERMITE
 INSPECTION.
  
 G) DOORS AND WINDOWS TYPE AND SIZES.
  
 H) SPECIFIC GRADE OF STRUCTURAL LUMBER TO BE USED ON
 WALLS AND ROOF FRAMING.
  
 5- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY BUILDING LOCATED AT 2300 N. JOG RD TO VERIFY IF
 IMPACT FEES ARE DUE. BRING BACK COUNTY STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE. REQUIRED BY
 THE COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE.
  
 6- BATHROOM LAYOUT SHOWN ON SHEET A-1.0 DOESN'T MATCH
 BATHROOM LAYOUT SHOWN ON SHEET A-2.0 AND SHEET A-2.1.
 REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 7- ROOF FRAMING PLAN:
 A) SPECIFY ALL RAFTERS CONNECTORS TO SHOW COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.
  
 B) PROVIDE CALCULATIONS SHOWING HOW THE CANTILEVERED
 OUTRIGGERS AS SHOWN ON PLANS (EAST AND WEST SIDE)
 PROVIDE SUPPORT FOR ALL LOADS REQUIRED BY SEC. R301.
 ALSO, PROVIDE A COMPLETE SECTION DETAIL THRU THIS AREA.
 SEC. 107.2.1.3 OF CITY AMENDMENTS.
  
 C) PROVIDE CALCULATIONS SHOWING HOW THE ROOF SHEATHING
 THICKNESS SPECIFIED ON THE ROOF FRAMING PLAN PROVIDE
 SUPPORT FOR ALL LOADS REQUIRED BY SEC. R301. COORDINATE
 THIS COMMENT WITH THE PREVIOUS COMMENT. SEC. 107.2.1.3
 CITY AMENDMENTS.
  
 D) SPECIFY ROOF SHEATHING FASTENING AS REQUIRED BY SEC.
 R803.2.3.1.
  
 E) SPECIFY CROSS VENTILATION SIZE AND LOCATION AS
 REQUIRED BY SEC. R806.
  
 8- SPECIFY BATHROOM VENTILATION AS REQUIRED BY SEC.
 R303.3.
  
 9- SHEET A-4.0:
 A) DETAIL #1 NEEDS: (1)BOTTOM PLATE FASTENING
 SPECIFICATIONS. (2)WOOD STUDS ATTACHMENT SPECIFICATIONS
 TO THE BOTTOM PLATE. (3)FOOTING SIZE. (4)FOOTING TO BE
 12" BELOW FINISH GRADE. (5)STUCCO THICKNESS.
 5/8"REQUIRED. (6)REQUIRED 6" CLEARANCE FROM FINISH
 GRADE FOR TERMITE INSPECTION. REMOVE STUCCO FINISH ON
 THE 6" CLEARANCE. SEC. 107.3.5.3 CITY AMENDMENTS.
  
 B) PROVIDE CALCULATIONS SHOWING THAT THE SIZE OF
 FOOTING REINFORCEMENT (7/16" BARS) SPECIFIED FOR THE
 FOOTING IS ADEQUATE. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 C) CLARIFY SIZE OF ROOFING RAFTERS. 2X8 OR 2 X 10?.
 COORDINATE DETAILS #4, #5 AND #6 WITH ROOF FRAMING
 PLAN. SEC. 107.2.1 CITY AMENDMENTS. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 D) DETAILS #4, #5 AND #6: SPECIFY WOOD STUDS CONNECTORS
 AT TOP AND BOTTOM. SEC. 107.3.5.3 CITY AMENDMENTS.
  
 E) WINDOW AND DOOR FRAMING DETAILS: SPECIFY HEADER
 CONNECTORS. SEC. 107.3.5.3 CITY AMENDMENTS.
  
 F) SPECIFY WALL SHEATHING FASTENING. SEC. 107.3.5.3
 CITY AMENDMENTS.
  
 G) PROVIDE COMPLETE AND CORRECT DRIP EDGE FASCIA
 DETAIL. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 H) SPECIFY ROOF AND WALL INTERIOR FINISHES. SEC.
 107.3.5.3 CITY AMENDMENTS.
  
 10- SPECIFY INSULATION ON ROOF AND WALLS. COORDINATE
 WITH THE ENERGY CALCULATIONS. SEC. 103.2.2 OF 2010
 FBC-ENERGY CONSERVATION.
  
 11- SHEET A-3.0: REVISE ALL HEIGHT DIMENSIONS. SEE
 OTHER COMMENTS FOR ROOF RAFTERS SIZE. ALSO, TAKE INTO
 CONSIDERATION THE ROOF SLOPE. ONE SIDE MUST BE HIGHER
 THAN THE OTHER. SEC. 107.2.1 CITY AMENDMENTS.
  
 12- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ENTRY DOOR. NEED TWO COPIES. ONLY ONE WAS PROVIDED.
  
 B) WINDOWS. NEED TWO COPIES. ONLY ONE WAS PROVIDED.
  
 C) ALL STRUCTURAL CONNECTORS SPECIFIED ON PLANS AND
 DETAILS. ***NOTE: PROVIDE ONLY THE PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 D) FLAT ROOF (LOW SLOPE ROOF). AND CLEARLY IDENTIFY
 SPECIFIC APPROVED ASSEMBLY TO BE INSTALLED. ***NOTE: IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES, THEN RAS 117 CALCULATIONS WILL BE REQUIRED
 AND THEY HAVE TO BE SIGNED AND SEALED BY AND ARCHITECT
 OR ENGINEER.
  
 E) HURRICANE SHUTTERS FOR THE ENTRY GLAZED DOOR. AND,
 PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE CITY
 SAMPLE.
  
 13- DESIGNER RESPONSIBLE FOR THE PLANS TO REVIEW AND
 APPROVE IN WRITING ALL PRODUCT APPROVALS AS REQUIRED BY
 SEC. 107.3.4.1 OF CITY AMENDMENTS.
  
 ***NOTE:
 PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  