2014-02-06 06:03:18 | BUILDING PLAN REVIEW |
| PERMIT: 14011502 |
| ADD:7915 S DIXIE HWY SUITE # 7731 |
| CONT: SISCA CONSTRUCTION |
| TEL: (561)248-9041 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. FEB. 06/ 2014 |
| ACTION: DENIED |
| |
| NOTE: ONE SET OF PLANS ARE MISSING A3.0, A4.0, A5.0, |
| A6.0 & A7.0 SHEETS. |
| |
| 1-5) COMPLIED. |
| |
| 6) 2ND REQUEST PROVIDE MANUFACTURERS CUT SHEETS FOR THE |
| RUBBER MATS, NO NEW A6.0 SHEET. SHEET A3.0 FLOOR |
| COVERINGS INDICATE THE USE OF RUBBER MATS RF-1 & RF-2, |
| PLEASE PROVIDE DOCUMENTATION THESE PRODUCTS ARE IN |
| OCMPLIANCE WITH THE 2010 FBC-B: |
| 804.4 INTERIOR FLOOR FINISH REQUIREMENTS. |
| IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR |
| COVERING MATERIALS IN EXIT ENCLOSURES, EXIT |
| PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES NOT |
| SEPARATED FROM CORRIDORS BY FULL-HEIGHT PARTITIONS |
| EXTENDING FROM THE FLOOR TO THE UNDERSIDE OF THE |
| CEILING SHALL WITHSTAND A MINIMUM CRITICAL RADIANT FLUX |
| AS SPECIFIED IN SECTION 804.4.1. |
| |
| 804.4.1 MINIMUM CRITICAL RADIANT FLUX. |
| INTERIOR FLOOR FINISH AND FLOOR COVERING MATERIALS IN |
| EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CORRIDORS SHALL |
| NOT BE LESS THAN CLASS I IN GROUPS I-1, I-2 AND I-3 AND |
| NOT LESS THAN CLASS II IN GROUPS A, B, E, H, M, R-1, |
| R-2 AND S. IN ALL AREAS, FLOOR COVERING MATERIALS SHALL |
| COMPLY WITH THE DOCFF-1 ?PILL TEST? (CPSC 16 CFR, PART |
| 1630). |
| |
| EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH |
| AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH |
| SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE |
| PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE |
| REQUIRED, AND MATERIALS COMPLYING WITH THE DOC FF-1 |
| ?PILL TEST? (CPSC 16 CFR, PART 1630) ARE PERMITTED IN |
| ANY AREA WHERE CLASS II MATERIALS ARE REQUIRED. |
| |
| 7-8) COMPLIED |
| |
| 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |