2014-04-22 16:50:19 | BUILDING PLAN REVIEW |
| PERMIT: 14011422 |
| ADD: 847 SOUTHERN BLVD. |
| CONT: CARLOS GONZALEZ |
| TEL: (561)386-8217 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: TUES. APRIL 22/ 2014 |
| ACTION: DENIED |
| |
| 1) 2ND REQUEST . ADDITIONAL INFORMATION IS REQUIRED, |
| THE PBC PROPERTY APPRAISERS WEB SITE LIST THIS PROPERTY |
| AS A CONVENIENCE STORE WITH GAS PUMPS? |
| WILL THE GAS PUMPS CONTINUE TO BE IN OPERATION? THE |
| PLANS INDICATE THIS BUILDING IS TO BE CONVERTED INTO A |
| CAFETERIA, THIS WOULD MEANS A RESTARAUNT THE PLANS DO |
| NOT SHOW A DINING ROOM. |
| |
| 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 |
| 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS THE |
| EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL |
| SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND |
| DOCUMENTS: A FLOOR PLAN |
| . 107.3.5.1 COMMERCIAL BUILDINGS: |
| 1.COMPLIED MERCANILE <50 OCCUPANTS. OCCUPANCY GROUP AND |
| SPECIAL OCCUPANCY REQUIREMENTS SHALL BE DETERMINED. |
| 2 COMPLIED. VB- NONSPRINKLERED. . MINIMUM TYPE OF |
| CONSTRUCTION SHALL BE DETERMINED (SEE TABLE 503). |
| 3. 2ND REQUEST: LIFE SAFETY PLAN TO SHOW; |
| OCCUPANCY LOAD GROSS / NET |
| MEANS OF EGRESS |
| EXIT ACCESS / EXIT DOORS NOT SHOWN, EXIT LIGHTS NOT |
| SHOWN |
| SEATING/ TABLE & CHAIRS |
| SHELVING UNITS |
| NOTE SHEET 4 OF 4 PLEASE PROVIDE IN THE EXISTING |
| DISPLAY ROOM THE LAYOUT OF DISPLAY TABLES, KIOSK OR |
| RACKS, SHOW THE COMMON PATH OF TRAVEL FOR THIS AREA. |
| PLEASE SHOW WORST CASE SENARIO, IT APPEARS THE COMMON |
| PATH OF TRAVEL MAY BE OVER THE ALLOWED 50 FEET. 2010 |
| FBC-B 1014.3. |
| |
| 4. 2ND REQUEST. ACCESSIBILITY REQUIREMENTS WILL NEED TO |
| BE MET PLEASE REVIEW : 2010 FBC-ACCESSIBILITY CODE |
| 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF |
| DISPROPORTIONALITY. |
| WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| ALARMS. |
| |
| PLEASE PROVIDE A WRITTEN DETAILED ACCOUNT WHERE THE 20% |
| OF THE CONTRACT VALUE ($3,000.00) WILL BE SPENT IN |
| ACCESSIBLE UPGRADES. FUNDS ARE TO BE SPENT IN THE ORDER |
| GIVEN IN THE ABOVE CODE REQUIREMENT. NOTE THIS AMOUNT |
| MAY INCREASE WITH ADDITIONAL WORK REQUIRED FOR CODE |
| COMPLIANCE. IT WOULD APPEAR THE UPGRADES WOULD NEED TO |
| TAKE PLACE IN MAKING A SINGLE UNISEX RESTROOM. 2010 |
| FBC-B 26.4.1.1 PLACES SERVING FOOD OR DRINK ON A |
| TAKE-OUT, CARRY-OUT OR DELIVERY BASIS ONLY WHICH |
| PROVIDE NO SEATING SHALL BE REQUIRED TO PROVIDE A |
| MINIMUM OF ONE BATHROOM ACCESSIBLE TO THE PUBLIC. |
| |
| |
| 5) 426.1 SCOPE. PUBLIC FOOD SERVICE ESTABLISHMENTS OR |
| FOOD ESTABLISHMENTS SHALL COMPLY WITH DESIGN AND |
| CONSTRUCTION STANDARDS AS DESCRIBED IN THE FOOD CODE, |
| CHAPTER 509 PART I OR CHAPTER 500, FLORIDA STATUTES, AS |
| APPLICABLE. |
| |
| NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS |
| MAY APPLY. SEE DEPARTMENT OF BUSINESS AND PROFESSIONAL |
| REGULATION (DBPR) RULE 61C-4, FLORIDA ADMINISTRATIVE |
| CODE CHAPTER 500 AND CHAPTER 509, FLORIDA STATUTES. |
| |
| 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |