2014-01-21 16:09:49RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- FLAT ROOF:
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (2
 COPIES) FOR THE NAIL ENHANCING AT PERIMETER AND CORNER
 AREAS AS REQUIRED BY GENERAL LIMITATION # 7 ON LAST
 PAGE OF NOA 13-0424.14 SUBMITTED. NAIL ENHANCING
 REQUIRED TO MEET THE DESIGN PRESSURES OF SEC. R301 OF
 2010 FBC-RESIDENTIAL.
  
 ***NOTE: WHEN DOING THE RAS 117 CALCULATIONS TAKE INTO
 CONSIDERATION THAT THIS BUILDING IS LOCATED ON EXPOSURE
 "C".
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL