2014-01-02 18:04:31 | BUILDING PLAN REVIEW |
| PERMIT: 13120574 |
| ADD: 4117 BROADWAY |
| CONT: DREAMWORKS CONSTRUCTION |
| TEL: (813)249-5541 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: THURS. JAN. 02/ 2014 |
| ACTION: DENIED |
| |
| 1) SHEET A-1 SHOWS THE DEMOLITION OF THE EXISTING |
| STOREFRONT AND ALSO THE NEW DESIGN. IN THE NEW |
| STOREFRONT DESIGN THERE IS A MEASUREMENT OF 7 INCHES, |
| NOT SHOWN ON THE DEMO PLAN, IS THIS A STRUCTURAL COLMN, |
| OR STRUCTURAL MULLION, 2010 WEST PALM BEACH AMENDMENTS |
| TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION, 2010 EDITION 107.2.1.3 ADDITIONAL |
| INFORMATION IS REQUIRED. |
| |
| 2) THE PRODUCT APPROVAL FOR THE FRONT DOORS, TRANSOM |
| AND SIDELIGHTS HAS LARGE MISSILE TESTING, NO PRODUCT |
| APPROVAL WAS SUBMITTED FOR THE STOREFRONT WINDOWS ONLY |
| NOA 09-0127.13 DESCRIPTION SOLUTIA INTERLAYER FOR |
| LAMINATED GLASS, NO LARGE MISSILE TESTING. |
| 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| COMPONENTS & CLADDING |
| |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(B) WINDOWS |
| JAMES A. WITMER CBO |