Notes |
Date |
Text |
2014-02-10 07:28:53 | APPROVED WITH EXCEPTION, REVISION REQUIRED | | SUBMIT 2 COPIES OF CORRECTED ENERGY CALCULATIONS THAT | | MATCH PLANS. | | | | NOTE: | | THE STRUCTURE IS LOCATED IN A SPECIAL FLOOD HAZARD | | AREA, DESIGNATED FLOOD ZONE A5. THE MINIMUM ELEVATION | | IS 7 FEET BFE PLUS THE ADDITIONAL 6" OF FREEBOARD | | REQUIRED BY CITY ORDINANCE. BASED ON CITY BUILDING | | DEPARTMENT RECORDS THE CUMULATIVE TOTAL COSTS OF WORK | | ON THIS BUILDING INCLUDING $32,000.00 FOR THE PROPOSED | | WORK IS $ 105,889.00. THE CONTRACTOR SUBMITTED AN | | APPRAISAL FROM CHARLEEN MCMANUS, SRA, OF ANDERSON & | | CARR, INC. STATING THE MARKET VALUE OF THE BUILDING | | IMPROVEMENTS TO BE $ 320,000.00. BECAUSE THE TOTAL OF | | PREVIOUS IMPROVEMENTS AND THE PROPOSED WORK IS LESS | | THAN 50 PERCENT OF THE MARKET VALUE, THIS IS NOT | | CONSIDERED A SUBSTANTIAL IMPROVEMENT. ACCORDING TO THE | | PROPERTY APPRAISER'S RECORDS THE STRUCTURE WAS BUILT IN | | 1935 AND HAS HAD NO SUBSTANTIAL IMPROVEMENTS PRIOR TO | | THE DATE OF THE INITIAL FIRM (MARCH 1, 1979) . | | THEREFORE THIS IS BUILDING IS CONSIDERED TO BE | | PRE-FIRM. BASED ON TABLE 6-1A IN FEMA PUBLICATION P-758 | | NEITHER THE LATERAL ADDITION NOR THE REMODEL IS | | REQUIRED TO COMPLY WITH NFIP REQUIREMENTS FOR NEW | | CONSTRUCTION. |
|