Plan Review Notes
Plan Review Notes For Permit 13100967
Permit Number 13100967
Review Stop B
Sequence Number 1
Notes
Date Text
2013-11-12 10:22:40PLEASE ADDRESS THE ITEMS NOTED BELOW:
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. IS THE
 PROPOSED TILE UNDERLAYMENT A BUR OR A PEEL & STICK TYPE
 PRODUCT? NOTE THE HISTORIC REVIEW REQUIRES A BARREL
 TILE, NOT AN "S." TILE.
 PROVIDE FURTHER DETAILS TO SPECIFY THE DIMENSIONS OF
 THE T&G ROOF SHEATHING AND ATTACHMENT METHOD (NAILING)
 TO THE RAFTERS.
 SPECIFY THE LOWER ATTACHMENT OF THE ANGLED 4X4 SUPPORTS
 TO THE EXISTING WALL.
 IT APPEARS ONLY TWO RAFTERS ARE PROPOSED RESULTING IN A
 ROOF SHEATHING SPAN OF 6'8".
 A LICENSED DESIGNER, FAMILIAR WITH WIND DESIGN LOADS
 SHOULD, EVALUATE THE PROPOSED DESIGN.
  
  
  
  


Account Summary | Usage Policy | Privacy Policy