2013-11-22 18:16:03NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE REVISED GEOTECHNICAL REPORT THAT REFLECTS
 THE ACTUAL PROPOSED 2 STORY CONCRETE BLOCK RESIDENCE
 AND THE INGROUND POOL IN CLOSE PROXIMITY TO THE
 BUILDING AS SHOWN ON THE SURVEY. SEE PROPOSED PLANS FOR
 THE ACTUAL SQUARE FOOTAGE OF THE HOUSE AND ALL COLUMNS
 SHOWN. SEC. R401.4 OF 2010 FBC-RESIDENTIAL AND SEC.
 107.2.1.3 CITY AMENDMENTS TO FBC.
  
 2- SPECIFY ON PLANS CARBON MONOXIDE ALARMS. SEC. R315
 OF 2010 FBC-RESIDENTIAL.
  
 3- SPECIFY THE ATTIC ATTIC LIVE LOAD AS REQUIRED BY
 TABLE R301.5 AND FOOTNOTES "B" AND "G".
  
 4- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR CONSTRUCTION OF SECOND FLOOR WALL ABOVE GARAGE
 AREA. SPECIFY ALL WALL FRAMING FRAMING MEMBERS, ALL
 BEAMS AND COLUMNS SUPPORTING THE BEAMS AND CONNECTORS.
 SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 5- SPECIFY FIRE RATING SPECIFICATIONS FOR GARAGE DOOR
 #5 AS REQUIRED BY SEC. R302.5.1 OF 2010
 FBC-RESIDENTIAL.
  
 6- PROVIDE COMPLETE STRUCTURAL BUCK DETAILS AND
 SPECIFICATIONS FOR GARAGE DOORS, ALL EXTERIOR SWING
 DOORS AND WINDOWS. SEC. R612.10.2 OF 2010
 FBC-RESIDENTIAL.
  
 7- PROVIDE FRAMING DETAILS AND SPECIFICATIONS FOR ALL
 ARCHED OPENINGS SHOWN ON PLANS. SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 8- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 INTERIOR BEARING WALL FOOTING. SEC. R301.1 OF 2010
 FBC-RESIDENTIAL.
  
 9- SPECIFY STAIR FIREBLOCKING. SEC. R302.11
 2010-FBC-RESIDENTIAL.
  
 10- COMPLETE DETAIL/SPECS FOR INTERIOR COLUMN BY
 STAIRWAY. SPECIFY SIZE AND ALL CONNECTORS. SEC. R301.1
 OF 2010 FBC-RESIDENTIAL.
  
 11- PROVIDE COMPLETE ENGINEERING CALCULATIONS FOR REAR
 PORCH COLUMNS FOOTING SIZE AS SHOWN ON PLANS. SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL.
  
 12- PROVIDE COMPLETE SECOND FLOOR FRAMING PLAN. SPECIFY
 ALL BEAMS, HEADERS, LINTELS, ALL PORCH BEAMS AND END
 CONNECTORS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 13- A) PROVIDE COMPLETE ROOF FRAMING PLAN SHOWING ALL
 BEAMS, LINTELS, HEADERS, ETC. INCLUDING THE ROUND ROOF
 ABOVE BEDROOM #3. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 B) PROVIDE COMPLETE WOOD FRAMING DETAILS AND FASTENING
 SPECIFICATIONS FOR THE CONSTRUCTION OF KNEE WALL ABOVE
 BEDROOM #3. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
  
 14- SHEET S-1:
 A) SPECIFY VAPOR BARRIER. SEC. R405.2.2 OF 2010
 FBC-RESIDENTIAL.
 B) FOOTING SHOWN ON FOUNDATION PLAN DOESN'T MATCH
 FOOTING SHOWN ON TYPICAL 2 STORY WALL SECTION. IS IT
 MONOLITHIC FOOTING OR STEMWALL?. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
 C) SPECIFY CONNECTORS FOR ALL TRUSS GIRDERS SHOWN ON
 FRAMING PLANS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL.
 D) PROVIDE COMPLETE DETAIL/SPECS FOR SOFFIT DETAIL.
 WHERE IS THE METHAL LATH ATTACHED TO. SEC. R703.1.3 OF
 2010 FBC-RESIDENTIAL.
 E) SPECIFY WALL INSULATION (CONCRETE BLOCK AND FRAMED
 WALLS), INSULATION ABOVE GARAGE. COORDINATE WITH THE
 ENERGY CALCULATIONS. SEC. 103.2.2 OF 2010 FBC-ENERGY
 CONSERVATION.
 F) SPECIFY FIREBLOCKING. ON SECOND FLOOR AND ON WALLS.
 SEC. R302.11 OF 2010 FBC-RESIDENTIAL.
 G) FLORIDA PRODUCT APPROVAL NUMBER FOR SIMPSON CAP AND
 BASE CONNECTORS SHOWN ON SECTION 1/S-1 IS NO CURRENT.
 PROVIDE CURRENT 2010 CODE VERSION. DCA RULE 9N-3.
 H) PORCH FOOTING SIZE SHOWN ON FOUNDATION PLAN DOESN'T
 MATCH SECTION 1/S-1. SEC. 107.2.1 CITY AMENDMENTS TO
 FBC.
  
 15-FLOOD ZONE A5.
 A) SPECIFY FINISH FLOOR ELEVATION AT GARAGE AND FIRST
 FLOOR.
 B) ELEVATION CERTIFICATES REQUIRED DURING CONSTRUCTION
 AND FINAL.
  
 16- DRAINAGE PLAN ON SHEET A-6 SHOWS 4" DECK DRAIN ON
 BACK PART OF BUILDING BY THE NEW POOL AREA. DRAWINGS ON
 SHEET S-2 SHOWS SLOPE TOWARDS THE POOL. COORDINATE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 17- SHEET S-2: PROVIDE ENGINEERING CALCULATIONS FOR
 RETAINING WALLS FOR POOL AND 2 STORY BUILDING. SEC.
 R301.1 OF 2010 FBC-RESIDENTIAL AND SEC. 107.2.1.3 CITY
 AMENDMENTS TO FBC.
  
 18- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) ARCHED ENTRY WOOD DOOR AS SHOWN ON PLANS.
  
 B) ROOF TILE ADHESIVE. NOA 10-1112.05 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. NEED TO PROVIDE CURRENT NOA.
  
 C) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. ***NOTE: PROVIDE ONLY THE PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
  
 19- PERSON RESPONSIBLE FOR THE DESIGN TO APPROVE IN
 WRITING ALL PRODUCT APPROVALS AS REQUIRED BY SEC.
 107.3.4.1 OF CITY AMENDMENTS.
  
 20- ENERGY CALCULATIONS:
 A) REVISE THE DOORS INFORMATION ON PAGE 3 OF 6 TO MATCH
 PLANS AND PRODUCT APPROVALS SUBMITTED. SEE NUMBER, TYPE
 AND SIZE OF WINDOWS SHOWN ON PLANS. FOR EXAMPLE THE
 ENTRY DOOR IS THE ONLY WOOD DOOR AND IS ONLY ONE. SEC.
 103.2.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 B) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF ENERGY
 CALCULATIONS FORM. SEC. 103.2.3.2 OF 2010 FBC-ENERGY
 CONSERVATION.
  
 21- REVISE ATTIC ACCESS DETAIL ON SHEET A-3: NEED 22"
 MIN. OPENING. SEE SEC. R807.1 OF 2010 FBC-RESIDENTIAL.
  
 22- SHEET A-5:
 A) REVISE PLYWOOD SHEATHING NAILING SCHEDULE FOR ROOF.
 ROOF NAILING ZONES ARE INCORRECT. SEE FIGURE R301.2.(7)
 OF 2010 FBC-RESIDENTIAL.
  
 B) IDENTIFY THE ROOF ZONES ON ROUND ROOF ABOVE BEDROOM
 #3. SEE FIGURE R301.2(7)
  
 C) REVISE NAILING SPACING FOR ROOF ZONE #3. NEED TO BE
 AT 4"O.C. AS REQUIRED BY SEC. R803.2.3.1 OF 2010
 FBC-RESIDENTIAL.
  
 23- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT
 FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  