Notes
Date Text
2013-10-28 17:38:45****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. DESIGN PROFESSIONAL FOR THE RENOVATION SPECIFIES
 BUILDING DESIGN PRESSURE AS 170; NOT CLEAR WHETHER THIS
 APPLIES TO SIGNAGE. SIGN ENGINEERING TO BE REVIEWED BY
 DESIGNER OF RECORD, FBC 1609, OR PROVIDE CLARIFICATION
 LETTER FROM HARTLEY PURDY ARCHITCTURE, OR REVISE
 ENGINEERING DESIGN TO 170MPH EXPOSURE C MINIMUM.
  
 2. PROPOSED FASTENING NOT CLEAR. THE SECTION ON THE
 LEFT SIDE OF THE PLAN SHOWS (5) 1/4" X 2" TPACONS; 5
 DOES NOT APPEAR TO BE ENOUGH FASTENERS FOR A 42" X 48"
 M-ARCH SIGN. INSTALL INSTRUCTIONS STATE LAG SCREWS AND
 WASHERS WILL BE USED FOR INSTALLATION; NOT CLEAR FOR
 WHICH OF THE SIGNS THIS APPLIES AND MINIMUM NUMBER OF
 FASTENERS NOT SPECIFIED.
  
 3. PROVIDE A VERIFIABLE CONTRACT FOR THIS JOB. VALUE IS
 TO INCLUDE LABOR, MATERIALS, AND ENGINEERING, EVEN IF
 THE MATERIALS ARE SUPPLIED BY OTHERS, FBC 109.
  
  
  