2013-11-02 12:54:311717 EDGAR STREET
 PERMIT #13100403
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 HEADROOM: THE BAR JOISTS ABOVE THE MEZZANINE ARE
 LOCATED WITHIN 7'-6" OF THE FLOOR DECK.
  
 STAIR HANDRAILS& GUARDRAILS: GUARDS, AT LEAST 42-INCHES
 TALL, SHALL BE PROVIDED AT THE OPEN SIDES OF MEANS OF
 EGRESS (STAIRS, MEZZANINE, ETC.) THAT EXCEED 30-INCHES
 ABOVE THE FLOOR. OPEN GUARDS SHALL PROHIBIT THE PASSAGE
 OF A 4-INCH DIAMETER SPHERE UP TO A HEIGHT OF
 34-INCHES. THE TRIANGULAR OPENINGS FORMED BY THE RISER,
 TREAD AND BOTTOM ELEMENT OF THE GUARDRAIL SHALL
 PROHIBIT THE PASSAGE OF A 6-INCH DIAMETER SPHERE.
 HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR.
 HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND
 NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD,
 MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE
 LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE
 RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT
 NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A
 DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN
 2 INCHES.
  
 STAIR RISERS: INDICATE THE HEIGHT OF THE STAIR RISERS.
  
 INDICATE THE LOCATIONS OF MEZZANINE LIGHTING. IS
 LIGHTING TO BE PROVIDED TO ILLUMINATE THE AREA BELOW
 THE MEZZANINE?
  
 STRUCTURES WITH LIGHT FRAME FLOOR CONSTRUCTION SHALL BE
 IDENTIFIED WITH A SIGN AFFIXED TO THE BUILDING. THE
 SIGN SHALL FEATURE A MALTESE CROSS 8-INCHES WIDE AND
 8-INCHES TALL AND BE OF A BRIGHT RED REFLECTIVE COLOR
 AND BEAR THE LETTER F DESIGNATION PER FLORIDA STATUTE
 633.027 AND FLORIDA ADMINISTRATIVE CODE 69A-60.0081.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  


Account Summary | Usage Policy | Privacy Policy