2013-12-05 10:18:06 | BUILDING PLAN REVIEW |
| PERMIT: 13090825 |
| ADD: 1155 BELVEDERE RD |
| CONT: TO BE DETERMINED/ FRITZ MASSON |
| TEL: (954)710-1118 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: THURSDAY DEC. 05/ 2013 |
| ACTION: DENIED |
| |
| 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| |
| 1) SHEET S1.01 STRUCTURAL DESIN / WIND DESIGN CRITERIA |
| THE PLANS HAVE BEEN UPDATED TO THE CORRECT BUILDING |
| CATEGORY II WITH ASSOCIATED WIND DESIGN OF 170 MPH, 3 |
| SECOND GUST BUT THE EXPOSURE HAS CHANGED FROM THE FIRST |
| REVIEW EXPOSURE "C" TO A EXPOSURE "B". THE CORRECT |
| EXPOSURE IS A "C" EXPOSURE THAT WILL AFFECT THE |
| PRESSURES AND PRODUCT APPROVALS. PLEASE REVIEW AND |
| UPDATE POSITIVE AND NEGATIVE PRESSURES ACCORDINGLY, |
| NOTE THERE IS A MULTIPLIER TO BE USED WITH A "C" |
| EXPOSURE. |
| |
| |
| |
| 2) 2ND REQUEST. UPDATE THE WIND LOAD/ PRESSURE CHART, |
| THIS CHART DOES NOT INDICATE IF THE AREA AFFECTED IS 10 |
| SF, 20, 50, OR 100 SF. NOR HEIGHT ADJUSTMENT FACTORS. |
| 2010 FBC-B TABLE 1609. |
| |
| 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| SHOP DRAWINGS ETC.. |
| |
| 4) PRESSURES WILL BE AFFECTED BY THE C EXPOSURE, AGAIN |
| THE COMMENT # 2 WAS NOT ADDRESSED THIS PORTION OF THE |
| REVIEW CAN NOT HAPPEN WITH OUT THE PRESSURES BROKE OUT |
| TO 10, 20, 50 OR 100 SQ FT. 2 010 FBC-B 1609.1.2 |
| PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & |
| CLADDING |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(A) EXTERIOR DOORS. |
| (B) WINDOWS |
| (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| LOUVERS, EFIS SYSTEMS, |
| (D) ROOFING PRODUCTS AND ASSEMBLIES |
| (E) SHUTTERS |
| (F) SKYLIGHTS |
| (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| STANDS |
| |
| 5) COMPLIED.. |
| |
| JAMES A. WITMER CBO |