Date |
Text |
2013-10-01 11:03:52 | BUILDING PLAN REVIEW |
| PERMIT:13090663 |
| ADD: 5600 N FLAGLER DR/ GARAGE |
| CONT: MURRAY LOGAN |
| TEL: (561)686-3948 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: SEPT. 30/ 2013 |
| ACTION: DENIED |
| |
| 1) THIS IS A 3 STORY STRUCTURE AND WILL REQUIRE A |
| RESIDENT INSPECTOR. WILL ALSO REQUIRE (3) SETS OF |
| PLANS. FBC* 109.3.7 RESIDENT INSPECTOR. SUBMIT |
| INSPECTOR RESUME' AND LICENSE DOCUMENTS TO KEN CONRAD |
| MANAGER OF THE RESIDENT INSPECTOR PROGRAM. A RESIDENT |
| INSPECTOR PROGRAM IS REQUIRED, CONTACT KEN CONRAD AT; |
| CHIEF BUILDING INSPECTOR |
| KEN CONRAD |
| TEL: 561-805-6666 |
| E-MAIL: [email protected] |
| |
| 2) THE STRUCTURAL PLANS BY PE CLARENCE RHEAULT INDICATE |
| THE EXPOSURE AS "C", PLEASE SEE THIS STRUCTURE IS |
| WITHIN 600 FEET OF THE INTERCOASTAL AND QUALIFIES AS A |
| "D" EXPOSURE. 2010 FBC-B 1609.4.3 EXPOSURE D. EXPOSURE |
| D SHALL APPLY WHERE THE GROUND SURFACE ROUGHNESS, AS |
| DEFINED BY SURFACE ROUGHNESS D, PREVAILS IN THE UPWIND |
| DIRECTION FOR A DISTANCE OF AT LEAST 5,000 FEET (1524 |
| M) OR 20 TIMES THE HEIGHT OF THE BUILDING, WHICHEVER IS |
| GREATER. EXPOSURE D SHALL EXTEND INLAND FROM THE |
| SHORELINE FOR A DISTANCE OF 600 FEET (183 M) OR 20 |
| TIMES THE HEIGHT OF THE BUILDING, WHICHEVER IS GREATER |
| FROM AN EXPOSURE D CONDITION AS DEFINED IN THE PREVIOUS |
| SENTENCE. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |