Plan Review Notes For Permit 13090500 |
Permit Number |
13090500 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-10-08 15:37:14 | 2010 FBC | | | | RE-ISSUE STRUCTURAL REVIEW IS DENIED | | | | 1) SCREEN ENCLOSURES ARE CONSIDERED RISK CATEGORY I | | WHICH EQUATES TO A 155 MPH VULT WINDSPEED FOR WEST PALM | | BEACH AND THIS STRUCTURE IS LOCATED IN EXPOSURE | | CATEGORY C. THE STRUCTURE IS REQUIRED TO BE DESIGNED TO | | WITHSTAND THESE WINDLOADS. FBC 1604 | | | | 2) THE PLAN INFORMATION THAT WAS SUBMITTED IS NOT | | ADEQUATE TO COMPLETE A STRUCTURAL REVIEW. SUBMIT (2) | | SETS OF SIGNED AND SEALED ENGINEERED PLANS WITH SPAN | | TABLES, SUPER GUTTER DETAILS, FOUNDATION DETAILS, | | ANCHORING DETAILS, MATING DETAILS, K BRACING DETAILS, | | ETC. FBC 2002.4 | | | | 3) FBC 2002.4.1 ALLOWS SCREEN ENCLOSURES TO BE DESIGNED | | USING THE 2010 EDITION OF THE AAF GUIDE TO ALUMINUM | | CONSTRUCTION IN HIGH WIND AREAS. IF THIS IS USED, | | SUBMIT (2) SETS OF PLANS WITH COPIES OF THE SPAN | | TABLES, SUPER GUTTER DETAILS, FOUNDATION DETAILS, | | ANCHORING DETAILS, MATING DETAILS, K BRACING DETAILS, | | ETC. THAT ARE TO BE USED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|