2013-10-08 15:37:142010 FBC
  
 RE-ISSUE STRUCTURAL REVIEW IS DENIED
  
 1) SCREEN ENCLOSURES ARE CONSIDERED RISK CATEGORY I
 WHICH EQUATES TO A 155 MPH VULT WINDSPEED FOR WEST PALM
 BEACH AND THIS STRUCTURE IS LOCATED IN EXPOSURE
 CATEGORY C. THE STRUCTURE IS REQUIRED TO BE DESIGNED TO
 WITHSTAND THESE WINDLOADS. FBC 1604
  
 2) THE PLAN INFORMATION THAT WAS SUBMITTED IS NOT
 ADEQUATE TO COMPLETE A STRUCTURAL REVIEW. SUBMIT (2)
 SETS OF SIGNED AND SEALED ENGINEERED PLANS WITH SPAN
 TABLES, SUPER GUTTER DETAILS, FOUNDATION DETAILS,
 ANCHORING DETAILS, MATING DETAILS, K BRACING DETAILS,
 ETC. FBC 2002.4
  
 3) FBC 2002.4.1 ALLOWS SCREEN ENCLOSURES TO BE DESIGNED
 USING THE 2010 EDITION OF THE AAF GUIDE TO ALUMINUM
 CONSTRUCTION IN HIGH WIND AREAS. IF THIS IS USED,
 SUBMIT (2) SETS OF PLANS WITH COPIES OF THE SPAN
 TABLES, SUPER GUTTER DETAILS, FOUNDATION DETAILS,
 ANCHORING DETAILS, MATING DETAILS, K BRACING DETAILS,
 ETC. THAT ARE TO BE USED.
  