2013-09-19 14:28:141. PROPOSED AWNING STYLE IS NOT CONSISTENT WITH
 EXISTING AWNINGS AROUND THE BUILDING. PLEASE USE THE
 OPEN SIDE AWNIGNS WITH SPEARS AS THE DON RAMON
 RESTAURANT.
 2. PLEASE PROVIDE INFORMATION TO CONFIRM LOCATION OF
 PROPOSED AWNING. AWNING SHALL BE SET BACK 4 FEET FROM
 THE FACE OF THE CURB.
 3. PLEASE INCLUDE CLEARANCE INFORMATION. AWNING SHALL
 BE MINIMUM 8' FROM SIDEWALK LEVEL.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
2013-09-16 08:38:16ZONING RECEIVED. ROUTED TO AAPONTE FOR REVIEW.