Plan Review Notes For Permit 13080811 |
Permit Number |
13080811 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-09-11 15:53:09 | BUILDING PROVISO: | | 1) DOOR TO LIQUOR CLOSET 101 NEEDS TO SWING INTO THE | | CLOSET. 2010 FBC-B 1008.1.9.11 DURING ITS SWING, ANY | | DOOR IN A MEANS OF EGRESS SHALL LEAVE UNOBSTRUCTED AT | | LEAST ONE HALF OF THE REQUIRED WIDTH OF AN AISLE, | | CORRIDOR, | | PASSAGEWAY, OR LANDING, NOR PROJECT MORE THAN 7 INCHES | | (178 MM) INTO THE REQUIRED WIDTH OF AN AISLE, CORRIDOR, | | PASSAGEWAY OR LANDING, WHEN FULLY OPEN. | | | | 2) 6" RAISED PLATFORM TO COMPLY WITH: 1003.5 ELEVATION | | CHANGE. WHERE CHANGES IN ELEVATION OF LESS THAN 12 | | INCHES | | (305 MM) EXIST IN THE MEANS OF EGRESS, SLOPED SURFACES | | SHALL BE USED. WHERE THE SLOPE IS GREATER THAN ONE UNIT | | VERTICAL IN 20 UNITS HORIZONTAL (5-PERCENT SLOPE), | | RAMPS COMPLYING WITH SECTION 1010 SHALL BE USED. | | | | 3) 2010 FL ACCESSIBILITY CODE 404.2.4 MANEUVERING | | CLEARANCES, 18 " PULL SIDE OF DOOR, | | 2010 FL ACC CODE 307.2 PROTRUSION LIMITS. OBJECTS WITH | | LEADING EDGES MORE THAN 27 INCHES (685 MM) AND NOT MORE | | THAN 80 INCHES (2030 MM) ABOVE THE FINISH FLOOR OR | | GROUND SHALL PROTRUDE 4 INCHES (100 MM) MAXIMUM | | HORIZONTALLY INTO THE | | CIRCULATION PATH. | | | | | | | | | | |
|