2013-08-20 11:53:43****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
 ****REVISION REQUIRED SUBJECT TO INSPECTOR'S
 DISCRETION****
  
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. REVISE FLOOR PLAN TO SHOW ROOM DESIGNATION FOR THE
 EMERGENCY MEANS OF ESCAPE, FBC R310.4:
  
 THE MEANS OF ESCAPE SHALL BE WITHIN THE FIRST FLOOR OF
 THE DWELLING OR DWELLING UNIT AND SHALL NOT BE LOCATED
 WITHIN A GARAGE WITHOUT A SIDE-HINGED DOOR LEADING
 DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY PART OF THE
 DWELLING OR DWELLING UNIT SHALL BE ABLE TO ACCESS THE
 MEANS OF ESCAPE WITHOUT PASSING THROUGH A LOCKABLE DOOR
 NOT UNDER THEIR CONTROL.
  
 IF COMPLIANCE WITH THIS CODE SECTION IS NOT CLEAR ON
 THE REVISED FLOOR PLAN TO BE PROVIDED AT INSPECTION,
 SUBJECT TO INSPECTOR'S DISCRETION A REVISION IS
 REQUIRED.
  