2013-08-23 15:31:21PERMIT #13080372
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) 2 SETS OF PLANS REQUIRED FOR SUBMITTAL.
  
 2) PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
 INCLUDE LOCATION OF EXTINGUISHERS ON PLANS.
  
 3) EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A
 MINIMUM OF 1.5 HOURS IN THE EVENT OF FAILURE OF NORMAL
 LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE
 ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT
 LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT,
 NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF
 EGRESS AT FLOOR LEVEL. INCLUDE LOCATION OF EMERGENCY
 LIGHTING FACILITIES, ON PLANS.
  
  