2013-09-03 13:58:10****PROVISO****
 ****REVISION REQUIRED PRIOR TO FIRST INSPECTION****
 ****ISSUED AT OWNER'S RISK****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. WIND SPEED DESIGN CRITERIA TOO LOW. SEE
 WWW.ATCOUNCIL.ORG/WINDSPEED, THIS LOCATION SHOULD BE
 169MPH MINIMUM. REVISE OR PROVIDE JUSTIFICATION FOR
 165MPH WIND SPEED.
  
 2. SPECIFY CONNECTORS, FBC 2010 RESIDENTIAL 301. THIS
 SHOULD INCLUDE BRAND AND CONNECTOR NAME.
  
 3. APPLICATION STATES "REROOF" INCLUDED IN SCOPE. IS
 THIS FOR THE ENTIRE HOUSE OR THE ADDITION? REVISE PLAN
 TO CLARIFY.
  
 4. THE SURVEY IS NOT CONSISTENT WITH SHEET A1, PLEASE
 CORRELATE.
  
 5. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 COMPONENTS & CLADDING (ROOF). INCLUDE FASTENING
 INFORMATION. THIS MAY BE SUBMITTED LATER AS A REVISION
 BUT PRIOR TO INSTALLATION.
  
  
  
  
  