2013-08-22 10:40:03RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- SHEET A0:
 A) REVISE THE BUILDING EXPOSURE SPECIFIED ON THE
 "DEVELOPMENT DATA" SPECIFICATIONS. ACCORDING TO SEC.
 R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL THIS BUILDING IS
 LOCATED ON EXPOSURE "C" NOT "B".
  
 B) REVISE THE WINDOWS/DOORS DESIGN PRESSURES TO
 CORRESPOND TO EXPOSURE "C". ***NOTE: REVISE PRESSURES
 ON WINDOW/DOOR SCHEDULES ALSO AND INCLUDE GARAGE DOOR.
  
 2- PLANS TO BE SIGNED AND SEALED BY FLORIDA LICENSED
 ARCHITECT OR ENGINEER. SEAL STAMPED ON "BASIL
 IRVING-SSC DESIGN GROUP" IS NOT FROM AN ARCHITECT OR
 ENGINEER. IT'S A CORPORATE SEAL. CORPORATE SEAL DOESN'T
 ENTITLE TO PRACTICE ARCHITECTURE OR ENGINEERING.
 FLORIDA STATUTE 481 AND 471.
 A) NEED ENGINEER OR ARCHITECT SEAL AND SIGNATURE ON ALL
 DRAWINGS. CHAPTER 471 OR 481 FLORIDA STATUTE.
  
 B) NEED FIRM FLORIDA LICENSE NUMBER FOR "SSC DESIGN
 GROUP". CHAPTER 481 FLORIDA STATUTE.
  
 3- PROVIDE ENERGY CALCULATIONS. SEC. 101.4.3 OF 2010
 FBC-ENERGY CONSERVATION. PLEASE MAKE SURE IS FILLED
 COMPLETELY AND SIGNED & DATED BY THE OWNER/AGENT ALSO.
  
 4- SHEET A1: REVISE GARAGE SWING DOOR SPECIFICATIONS ON
 THE DOOR SCHEDULE. NEED TO COMPLY WITH FIRE RATING OF
 SEC. R302.5.1 OF 2010 FBC-RESIDENTIAL.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 B) INSWING WOOD DOOR AS SHOWN ON PLANS FOR NEW CABANA
 BATHROOM.
  
 C) GARAGE DOOR FOR SIZE SHOWN ON PLANS. AND, CLARIFY IF
 REPLACING GARAGE DOORS OR NOT. FLOOR PLAN ON SHEET A2
 SAYS "RETAIN EXT OVERHEAD DOOR" AND, SPECIFY THE DESIGN
 PRESSURES.
  
 D) SLIDING GLASS DOORS AS SHOWN ON PLANS.
  
 E) FRENCH DOORS AS SHOWN ON PLANS.
  
 F) WINDOW MULLIONS AS SHOWN ON PLANS.
  
 G) FIXED WINDOWS. NOA 11-1110.15 SUBMITTED WAS
 SUPERSEDED BY MIAMI-DADE. NEED CURRENT NOA.
 ***NOTE: ALSO, NEED PRODUCT APRPOVAL FOR ALL WINDOW
 SIZES SHOWN ON PLANS. SEE WINDOW SCHEDULE.
  
 6- PRODUCT APPROVALS TO BE REVIEWED AND APPROVED IN
 WRITING BY THE ENGINEER OF RECORD (NOT SIGNING AND
 SEALING). SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
 ***NOTE: PRODUCT APPROVALS HAVE A CORPORATE SEAL. THIS
 DOESN'T ENTITLE TO PRACTICE ARCHITECTURE OR
 ENGINEERING. FLORIDA STATUTE 471 AND 481.
  
 7- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOM AS
 REQUIRED BY SEC. R315.
  
 8- PROVIDE COMPLETE INSTALLATION SCHEDULE FOR THE
 INSTALLATION OF SHUTTERS. NEED THIS INSTALLATION
 SCHEDULE TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES
 OF PRODUCT APPROVAL PROPOSED INSTALLATION AND THE
 DESIGN PRESSURES REQUIRED BY SEC. R301.2.1.4.3.
  
 ****NOTE: PROVIDE COMPLETE INFORMATION UNDER SEPARATE
 PERMITS FOR: POOL WORK, NEW GENERATOR, SCREEN ENCLOSURE
 WORK, GAS WORK, ETC.
  