2013-08-15 15:22:45 | BUILDING PLAN REVIEW |
| PERMIT: 13071119 |
| ADD: 1617 N FLAGLER DR # 602 |
| CONT: ED'S ISLAND TIME SERVICES, INC |
| TEL: (561)541-0004 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: AUGUST 15, 2010 |
| ACTION: PROVISO |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| 1) ID-02 PLANS INDICATE THE USE OF TRIM, NOT SPECIFIED |
| IF WOOD OR FOAM. |
| 2010 FBC-B 806.3 FOAM PLASTIC. |
| FOAM PLASTIC USED AS TRIM IN ANY OCCUPANCY SHALL COMPLY |
| WITH SECTION 2604.2. |
| 2604.2 INTERIOR TRIM. |
| FOAM PLASTIC USED AS INTERIOR TRIM SHALL COMPLY WITH |
| SECTIONS 2604.2.1 THROUGH 2604.2.4. |
| [F] 2604.2.1 DENSITY. |
| THE MINIMUM DENSITY OF THE INTERIOR TRIM SHALL BE 20 |
| PCF (320 KG/M3). |
| [F] 2604.2.2 THICKNESS. |
| THE MAXIMUM THICKNESS OF THE INTERIOR TRIM SHALL BE 1/2 |
| INCH (12.7 MM) AND THE MAXIMUM WIDTH SHALL BE 8 INCHES |
| (204 MM). |
| [F] 2604.2.3 AREA LIMITATION. |
| THE INTERIOR TRIM SHALL NOT CONSTITUTE MORE THAN 10 |
| PERCENT OF THE SPECIFIC WALL OR CEILING AREAS TO WHICH |
| IT IS ATTACHED. |
| [F] 2604.2.4 FLAME SPREAD. |
| THE FLAME SPREAD INDEX SHALL NOT EXCEED 75 WHERE TESTED |
| IN ACCORDANCE WITH ASTM E 84 OR UL 723. THE |
| SMOKE-DEVELOPED INDEX SHALL NOT BE LIMITED. |
| EXCEPTION: WHEN THE INTERIOR TRIM MATERIAL HAS BEEN |
| TESTED AS AN INTERIOR FINISH IN ACCORDANCE WITH NFPA |
| 286 AND COMPLIES WITH THE ACCEPTANCE CRITERIA IN |
| SECTION 803.1.2.1, IT SHALL NOT BE REQUIRED TO BE |
| TESTED FOR FLAME SPREAD INDEX IN ACCORDANCE WITH ASTM E |
| 84 OR UL 723. |
| |
| 2) A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| 2B) FBC-B 2010 603.2 EXCEPTION (1) TILE FLOORING |
| FLOOR INSULATION PLACED BETWEEN TWO LAYERS OF |
| NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING |
| AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX |
| OF NOT MORE THAN 100. |
| |
| 2C) FBC-B 2010 603.2 EXCEPTION 2 WOOD FLOORS |
| INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| |
| FBC-B 2010 |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |