2013-09-10 14:29:02COMMENTS FOR 13071001
 09/10/2013
  
 IN MANY PARTS OF THE CITY THE ABSENCE OF ANY STORMWATER
 BMP (STORMWATER BEST MANAGEMENT PRACTICES) IN SITES
 ALLOWS THE BOTH THE WATER VOLUME AND
 CONTAMINANT/POLLUTANT LOAD TO ENTER OUR SYSTEM
 UNTREATED. WHILE WE BELIEVE OUR EXISTING SYSTEM IS
 SUFFICIENT TO SERVICE THE STORMWATER VOLUME FOR YOUR
 PROPOSED USE, WE RECOGNIZE THAT THE FIRST FLUSH FROM
 THE PARKING AREA CONTAINS 90% OF THE
 CONTAMINANT/POLLUTANT LOAD FROM RAIN EVENTS AND THIS
 LOADING IS TRANSFERRED TO THE CITY?S STORMWATER SYSTEM.
  
 ACCORDINGLY, THE CITY HAS THE AUTHORITY TO IMPOSE
 STORMWATER BMP?S ON THE ENTIRE SITE WITH OR WITHOUT THE
 PROGRESSION OF THE PROPOSED WORK. HOWEVER, IN
 CONSIDERATION OF THE SCOPE OF THE PROPOSED
 IMPROVEMENTS, THE CITY HAS THE AUTHORITY TO THROTTLE
 IMPLEMENTATION OF BMP?S. IN THIS CASE, OUR
 RECOMMENDATION IS THAT YOU AS THE PROPERTY OWNER SHALL
 DESIGN AND MODIFY THE EXISTING STORMWATER
 INFRASTRUCTURE SERVING THE EXISTING PARKING AND PAVED
 AREA THAT HAS BEEN IDENTIFIED BY THE PLANNING AND
 ZONING DEPARTMENT AS REQUIRED TO SUPPORT THE PROPOSED
 BUILDING USE.
  
 ANY MODIFICATION SHALL INCORPORATE STORMWATER BMP?S
 SUFFICIENT TO DETAIN THE FIRST FLUSH FROM THE
 REFERENCED PAVED AREA. OWNER MAY PROPOSE AN ISOLATED
 SYSTEM THAT DETAINS AND PERCOLATES. PLEASE REFER TO THE
 SOUTH FLORIDA WATER MANAGEMENT DISTRICT MANUAL, IT;S A
 GOOD GUIDE TO SEE THE OPTIONS THAT MAY WORK WITH YOUR
 SITE. PLEASE LOOK AT THE OPTIONS FOR NONSTRUCTURAL
 BMP'S AND STRUCTURAL BMP'S. WE BELIEVE ANY OF THESE
 MODIFICATIONS REFLECT REASONABLE IMPROVEMENTS TO THE
 EXISTING CONDITIONS AND ARE CONSISTENT WITH PRACTICES
 OF BOTH THE CITY AND SOUTH FLORIDAWATER MANAGEMENT
 DISTRICT. PLEASE PROVIDE STORM CALCULATIONS WITH YOUR
 PLAN REVISIONS. INCLUDE PERVIOUS AND IMPERVIOUS
 QUANTITIES SO THAT WE MAY UPDATE YOUR STORM WATER
 ACCOUNT.
  
 HTTP://WWW.SFWMD.GOV/PORTAL/PAGE/PORTAL/XREPOSITORY/SFW
 MD_REPOSITORY_PDF/BMP_MANUAL.PDF
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved