2013-09-11 09:07:12 | 1. FINAL CONFIGURATION OF HIBISCUS STREET STREETSCAPE |
| IS CONTINGENT TO SUBMITTAL OF REVISED STREET SURVEY AND |
| DISCUSSIONS WITH THE ENGINEERING DEPARTMENT. |
| 2. STREET LIGTHS SHALL BE THE CITY STANDARD, AND |
| LOCATED TWO FEET FROM THE BACK OF THE CURB TO TEH |
| CENTER OF THE POLE ("LUMEC" CAT |
| #175MH-L50-PCFC-SE3-OTA/240V-SFO-1-BKTX BLACK). THE |
| FIXTURE SHALL BE LED. |
| 3. PARKING SPACES ON THE WEST SIDE OF THE DROP-OFF-AREA |
| SHALL BE COMPACT SPACES TO ALLOW FOR THE REQUIRED 5 |
| FEET LANDSCAPE BUFFER. |
| 4. PLANTING AREA ALONG THE ALLEY SHALL BE PROTECTED |
| WITH A CURB OR BOLLARDS. |
| 5. BASE PLANTING SHALL BE INSTALLED ALONG THE BUILDING |
| AS REQUIRED IN CONDITION OF APPROVAL FROM DAC, AND |
| PRESENTED FOR THE SITE PLAN APPROVAL. |
| 6. ROOT BARRIERS ARE REQUIRED AROUND STREET TREET, AND |
| 10 FEET OF STRUCTURAL SOIL SHALL BE INSTALLED AROUND |
| THE TREE GRATES PROPOSED ALONG THE SIDEWALK. |
| 7.THE NORTH PORTION OF THE ENTRY PLAZA CANNOT BE |
| SEPARATED WITH THE PROPOSED FENCE AND GATE.THE ENTRY |
| PLAZA SHALL BE MAINTAINED AS A PUBLIC OPEN SPACE. |
| 8. EXISTING DROP CURB ON DIXIE HWAY (CLOSER TO GARDENIA |
| STREET) SHALL BE REMOVED AND REPLACED BY A REGULAR |
| CURB. PLEASE DISCUSS WITH THE ENGINEERIGN DEPARTMENT |
| THE REQUIRED CURB TYPE. |
| 9. A NEW LIVE OAK SHALL BE PLANTED IN A TREE GRATE |
| ALONG DIXIE HWAY, 30 FEET NORTH OF THE EXISTING TREE IN |
| FRONT OF THE SURFACE PARKING LOT. |
| 10.PROPOSED LIGHT POLES IN MIDDLE ISLANDS MAY CONFLICT |
| WITH PROPOSED LANDSCAPE. PLEASE RELOCATE LIGHT POLES OR |
| DEMONSTRATE THERE IS NO CONFLICT. |
| 11. ALL FENCES AND GATES ALONG THE FRONTAGE LINE WITHIN |
| THE FRONT SETBACK SHALL BE A MAXIMUM OF 4 FEET. FENCES |
| WITHIN THE SIDE OR REAR SETBACK SHALL NOT BE MORE THAN |
| 6' IN HEIGHT. |
| 12. PLEASE INCLUDE A DIAGRAM INDICATING THE AREAS |
| CALCULATED FOR THE PRIVATE OPEN SPACE AND HOW IT |
| COMPLIES WITH THE MINIMUM 30% VEGETATED AREA, AND 20% |
| TREE CANOPY REQUIRED. SYNTETHIC TURF IS NOT CONSIDERED |
| VEGETATED AREA. |
| 13. PLANTING AREA ADJACENT TO DROP OFF ENTRANCE IS ONLY |
| 20". PLEASE VERIFY THAT WIDTH IS SUFFICIENT TO |
| ACCOMODATE AND ALLOW HEALTHY GROWTH OF PROPOSED |
| LANDSCAPE. |
| 14. PORTE COCHERE ROOF TREATMENT SHALL INCLUDE |
| ADDITIONAL TREATMENT AS PRESENTED IN RENDERS FOR THE |
| DAC SPECIAL REVIEW APPROVAL. |
| 15.PLEASE INCLUDE PROPERTY LINE IN ALL FLOOR PLANS, |
| ELEVATIONS, AND SECTIONS. |
| 16. ANY MECHANICAL EQUIPMENT ON ROOF TOP SHALL BE |
| SCREENED FROM VIEW. PLEASE PROVIDE INFORMATION TO |
| CONFIRM COMPLIANCE. |
| 17. ALL ROOF MEMBRANES SHALL INCLUDE A SOLAR |
| REFLECTANCE INDEX (SRI) GREATER THAN OR EQUAL TO 78. |
| PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE. |
| 18. . BUILDING AREA INCLUDED IN SHEET C-06 IS |
| 104,549SF, WHILE BUILDING AREA INCLUDED IN SHEET A1-01 |
| IS 107,996SF. PLEASE VEFIRY ALL THE INFORMATION AND |
| CREATE ONE SINGLE TABLE BASED ON THE DEFINITION OF |
| GROSS BUILDING AREA IN THE ZONING CODE.PLEASE INCLUDE |
| DIAGRAMS INDICATING THE AREAS INCLUDED IN THE TOTAL |
| GROSS BUILDING AREA IN EACH FLOOR, AND THE TOTAL |
| MECHANICAL AREA. PLEASE INCLUDE THE FAR CALCULATION AND |
| THE TOTAL AMOUNT OF TDRS NEEDED. |
| 19. PLEASE INCLUDE A NOTE IN THE DRAWINGS INDICATING |
| THE PARKING IS PROVIDED OFF-SITE BASED ON DAC APPROVAL |
| (DAC CASE NO. 13-04). |
| 20. PLEASE INCLUDE A TABLE TO CONFIRM COMPLIANCE FOR |
| THE MINIMUM 15% FENESTRATION REQUIREMENT ON EACH |
| ELEVATION(TABLE IV-4:FACADE ARTICULATION REQUIREMENTS). |
| FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| APONTE AT 561-822-1439. |
| |
| |
| 3. |
| LANDSCPAE PERMTI SHALL BE SUBMITTEDAS A SEPARATE PERMIT |
| FOR REVIEW. |