Plan Review Notes For Permit 13061122 |
Permit Number |
13061122 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-06-29 05:24:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. DOCUMENTS SUBMITTED INDICATE A SELF ADHERED | | UNDERLAYMENT, BUT A MIAMIDADE NOA WAS PROVIDED. PLEASE | | CLARIFY FASTENING/INSTALLATION METHOD PROPOSED FOR | | UNDERLAYMENT. THE NOA PROVIDED REQUIRES A BASE SHEET. | | | | 2. PARCEL IS LOCATED IN EXPOSURE C, FBC 2010 | | RESIDENTIAL 301. REVISE SUBMITTALS. | | | | 3. DOCUMENTS SUBMITTED INDICATE THAT POLYFOAM IS | | PROPOSED. PROVIDE PRODUCT APPROVAL, TWO SETS, FAC9N-3, | | FBC RESIDENTIAL 2010 301. | | |
|