Date |
Text |
2013-08-17 11:01:27 | BUILDING PLAN REVIEW |
| PERMIT: 13061104 |
| ADD: 5800 S DIXIE |
| CONT: MIKE MOORE |
| TEL: (561)301-9468 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: AUGUST 17/2013 |
| ACTION: DENIED |
| |
| FROM 1ST REVIEW, QUESTION WAS ASKED IF THIS BUILDING IS |
| FIRE SPRINKLERED, NOT PROVIDED, ASSUMED FOR THIS PLAN |
| REVIEW, NON-SPRINKLERED. |
| |
| 1) SHEET A1.1: THE CONTRACTOR WILL NEED TO UPDATE THE |
| EXISSTING PERMIT APPLICATION AND APPLY FOR A SECOND |
| PERMIT APPLICATION. THE PLANS INDICATE THE SPLITING OF |
| A SINGLE TENANT SPACE INTO TWO INDIVUAL TENANT SPECES |
| BY CREATING A TENANT SEPERATION WALL. THE CURRENT |
| PERMIT APPLICATION UNDER THE DESCRIPTION OF WORK ONLY |
| LIST A DEMISSING WALL. THE PLANS REFLECT ALSO THE |
| CREATION OF TWO RESTROOMS, ONE IN EACH TENANT SPACE. |
| NOTE THE VALLUE FOR THE NEW TENANT SEPERATION WALL, 2 |
| NEW RESTROOM WALLS, AND THE OUTFITTING OF RESTROOMS IS |
| ONLY $1,500.00. |
| |
| 1A) ON THE EXISTING PERMIT APPLICATION UPDATE THE |
| DESCRIPTION OF WORK, ADD A SUITE NUMBER TO THE |
| APPLICATION AND INCREASE THE VALUE OF WORK TO BE |
| COMPLETED UNDER THIS PERMIT. |
| CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF |
| THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER |
| ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL |
| REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, |
| PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE |
| WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), |
| ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION |
| REFRENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF |
| NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| 1B) SUBMIT A SECOND PERMIT PERMIT APPLICATION UPDATE |
| THE DESCRIPTION OF WORK, ADD A SUITE NUMBER TO THE |
| APPLICATION AND INCREASE THE VALUE OF WORK TO BE |
| COMPLETED UNDER THIS PERMIT. |
| CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF |
| THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER |
| ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, |
| VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL |
| REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, |
| PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE |
| WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), |
| ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION |
| REFRENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF |
| NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS |
| FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| CONGRESS. |
| |
| 1C) NOTE INDICATES THE CHOICE OF TWO 1 HOUR UL RATINGS |
| FOR THE 1 HOUR TENANT SEPERATION WALL. PLEASE SUBMIT |
| ONE UL DESIGN AND PRODUCE THE DESIGN ON THE PLANS, |
| INSPECTORS DO NOT CARRY A UL BOOK IN THEIR CAR. |
| CITY OF WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. SUCH |
| DRAWINGS AND SPECIFICATIONS SHALL CONTAIN INFORMATION, |
| IN THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS |
| A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. |
| |
| PLEASE NOTE SOME OF THE UL LISTINGS INDICATE TO TAKE |
| THE WALL TO THE CEILING LINE. PLEASE REVIEW2010 FBC-B |
| 709.4 CONTINUITY. |
| FIRE PARTITIONS SHALL EXTEND FROM THE TOP OF THE |
| FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE |
| UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK |
| ABOVE OR TO THE FIRE-RESISTANCE-RATED FLOOR/CEILING OR |
| ROOF/CEILING ASSEMBLY ABOVE, AND SHALL BE SECURELY |
| ATTACHED THERETO. IF THE PARTITIONS ARE NOT CONTINUOUS |
| TO THE SHEATHING, DECK OR SLAB, AND WHERE CONSTRUCTED |
| OF COMBUSTIBLE CONSTRUCTION, THE SPACE BETWEEN THE |
| CEILING AND THE SHEATHING, DECK OR SLAB ABOVE SHALL BE |
| FIREBLOCKED OR DRAFTSTOPPED IN ACCORDANCE WITH SECTIONS |
| 717.2 AND 717.3 AT THE PARTITION LINE. THE SUPPORTING |
| CONSTRUCTION SHALL BE PROTECTED TO AFFORD THE REQUIRED |
| FIRE-RESISTANCE RATING OF THE WALL SUPPORTED, EXCEPT |
| FOR WALLS SEPARATING TENANT SPACES IN COVERED MALL |
| BUILDINGS, WALLS SEPARATING DWELLING UNITS, WALLS |
| SEPARATING SLEEPING UNITS AND CORRIDOR WALLS, IN |
| BUILDINGS OF TYPE IIB, IIIB AND VB CONSTRUCTION. |
| |
| 1D) THE PLANS DO NOT INDICATE WHICH WAY THE ROOF |
| FRAMING MEMBERS ARE DESIGNED, IF THE ROOF FRAMING |
| MEMBERS PENETRATE THE NEW 1 HOUR FIRE RATED WALL OR |
| THERE IS ANY OTHER PENETRATIONS OF THE 1 HOUR RATED |
| WALL COMPLIANCE WITH 2010 FBC-B 709.7 PENETRATIONS. |
| PENETRATIONS OF FIRE PARTITIONS SHALL COMPLY WITH |
| SECTION 713. |
| 713.3.1 THROUGH PENETRATIONS. |
| THROUGH PENETRATIONS OF FIRE-RESISTANCE-RATED WALLS |
| SHALL COMPLY WITH SECTION 713.3.1.1 OR 713.3.1.2. |
| 713.3.1.1 FIRE-RESISTANCE-RATED ASSEMBLIES. |
| PENETRATIONS SHALL BE INSTALLED AS TESTED IN AN |
| APPROVED FIRE-RESISTANCE-RATED ASSEMBLY. |
| |
| 713.3.1.2 THROUGH-PENETRATION FIRESTOP SYSTEM. |
| THROUGH PENETRATIONS SHALL BE PROTECTED BY AN APPROVED |
| PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN |
| ACCORDANCE WITH ASTM E 814 OR UL 1479, WITH A MINIMUM |
| POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH (2.49 PA) |
| OF WATER AND SHALL HAVE AN F RATING OF NOT LESS THAN |
| THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL |
| PENETRATED. |
| |
| 1E) 2010 FBC-B 713.6 |
| FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE |
| BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL |
| REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE |
| EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR |
| STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY |
| HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE |
| ANY DECORATIVE CEILING AND IN CONCEALED SPACES. |
| SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: ?FIRE |
| AND SMOKE BARRIER ? PROTECT ALL OPENINGS.? |
| |
| 1F) PLEASE REVIEW PLUMBING COMMENTS ABOUT THE |
| ACCESSIBLE RESTROOM THAT IS DESIGNED WITH THE OUTSIDE |
| DIMENSION OF 7'-2", THE MINIMUM INTERIOR DIMENSION IS |
| 7'-1". 2010 FL ACC CODE FIGURE 604.8.1.6. |
| |
| SUGGEST A MEETING BEFORE PLANS ARE RESUBMITTED TO |
| REVIEW AND MAKE SURE A PERMIT WILL BE ABLE ISSUED UNDER |
| THE NEXT REVIEW!!!! |
| |
| INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |