2013-11-22 15:47:57 | BUILDING PLAN REVIEW |
| PERMIT:13060638 |
| ADD: 114 S OLIVE |
| CONT: TBD |
| TEL: (561)856-6655 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 3RD REVIEW |
| DATE: NOV. 22/2013 |
| ACTION: DENIED |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 1) THIS BUILDING QUALIFIES AS A THRESHOLD BUILDING, |
| MEETING THE DEFINITION. |
| DEFINITION: FL S. S. 553.71(7) " THRESHOLD BUILDING" |
| MEANING ANY BUILDING WHICH IS GREATER THAN (3) STORIES |
| OR 50 FT IN HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY |
| CLASSIFICATION AS DENIED IN THE FLORIDA BUILDING CODE |
| WHICH EXCEEDS 5,000 SQ FT IN AREA AND AN OCCUPANT |
| CONTENT OF GREATER THAN 500 PERSONS. |
| |
| 1A) COMPLIED 11/22/2013 |
| 1B) 2ND REQUEST, THRESHOLD INSPECTOR: |
| WPB AMENDMENT 109.3.6.2 W.P.B. CONSTRUCTION SERVICES |
| DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL |
| INSPECTOR AS REQUIRED BY FL S S 553.79(5) FLORIDA |
| STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY THIS |
| CODE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL |
| INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER |
| INFORMATION |
| BEFORE THE PERMIT MAY BE ISSUED. |
| |
| 1C) 2ND REQUEST, THRESHOLD BLDG, REQUIRED STATEMENT: |
| W.P.B. AMENDMENT 109.3.6.4.4 ALL PLANS FOR THE BUILDING |
| WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE |
| ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT |
| THAT, TO THE BEST OF THE ARCHITECT'S PR ENGINEER'S |
| KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE |
| APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE |
| LOCAL AUTHORITY IN |
| ACCORDANCE WITH THIS SECTION AND 633 FLORIDA STATUTE. |
| |
| ------------------------------------------------------- |
| ----------------------------------- |
| |
| 1D) 2ND REQUEST, 109.3.6 THRESHOLD BUILDINGS, OPERATING |
| GUIDELINES FOR THRESHOLD INSPECTORS #26. ASSURE THAT |
| THE DESIGNER HAS REQUIRED ON THE PLANS OR |
| SPECIFICATIONS ONE MATERIAL, APPROVED FOR FIRE STOPPING |
| PENETRATIONS, FOR WALLS AND CEILINGS. |
| ------------------------------------------------------- |
| ------------------------------------- |
| |
| 1E) 2ND REQUEST, A THRESHOLD PLAN REVIEW STOP WILL BE |
| PUT ON THIS PROJECT UNTIL THESE ITEMS ARE COMPLETED AS |
| REQUESTED BY THE CHIEF BUILDING INSPECTOR KEN CONRAD: |
| |
| PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED |
| TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| INSPECTIONS. |
| |
| 1E)(1) 2ND REQUEST, THE CONTRACTOR WILL PRODUCE A JOB |
| SUMMARY OR HISTORY FOR THIS TYPE OF CONSTRUCTION. |
| THIS MAY BE SUBMITTED TO KEN CONRAD BY E-MAIL. KEN |
| CONRAD: [email protected] |
| |
| 1E)(2) 2ND REQUEST, FOR THE SPECIAL INSPECTOR PLEASE |
| PROVIDE A RESUME' OF INSPECTION EXPERIENCE ON PREVIOUS |
| PROJECT. THE RESUME' MUST BE ACCOMPANIED BY ALL |
| CERTIFICATES AS SPECIFIED HEREIN. THE BUILDING OFFICIAL |
| OR HIS DESIGNEE WILL REVIEW THE RESUME'. AFTER THE |
| RESUME' IS REVIEWED, AN INTERVIEW WILL BE SCHEDULED. |
| UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED |
| FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA. |
| CONTACT KEN CONRAD |
| TEL: 561-805-6666 |
| E-MAIL: [email protected] |
| |
| 2) 2ND REQUEST, SHEET S1.1 THE EXISTING 6 COLUMNS |
| INDICATE TO INCREASE THE LOADS ON THESE COLUMNS TO |
| 6,000 PSF, TO SEE THE GEOTECHNICAL REPORT FOR |
| REQUIREMENTS. PLEASE PROVIDE 3 SIGNED/ SEALED ORIGINAL |
| SOILS REPORTS. 2010 FBC-B 1803.3 BASIS OF |
| INVESTIGATION. 1803.3.1 SCOPE OF INVESTIGATION. THE |
| SCOPE OF THE GEOTECHNICAL INVESTIGATION INCLUDING THE |
| NUMBER AND TYPES OF BORINGS OR SOUNDINGS, THE EQUIPMENT |
| USED TO DRILL OR SAMPLE, THE IN-SITU TESTING EQUIPMENT |
| AND THE LABORATORY TESTING PROGRAM SHALL BE DETERMINED |
| BY A REGISTERED DESIGN PROFESSIONAL. |
| |
| 3) COMPLIED, 11/22/2013. |
| |
| 4) 2ND REQUEST PRODUCT APPROVALS: |
| 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| COMPONENTS & CLADDING |
| FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| (31)(D) ROOFING PRODUCTS AND ASSEMBLIES |
| THE PRODUCT APPROVAL NOA 13-0606.02 CETCO STRATASEAL HR |
| HOT APPLIED LIQUID MEMBRANE WILL NEED TO SHOW ITS: ( |
| GENERAL LIMITATIONS) |
| FIRE CLASSIFICATION FOR A TYPE II-A BUILDING. |
| THIS PRODUCT IS NOT TO BE EXPOSED TO TRAFFIC, HOW WILL |
| IT BE PROTECTED. |
| NOT TO BE INSTALLED ON LIGHTWEIGHT CONCRETE, WHERE AS |
| THE OTHER ROOFING APPROVAL NOA 12-0703.09 IS TO BE |
| INSTALLED ON LIGHT WEIGHT CONCRETE. |
| FLASHINGS TO COMPLY WITH THE MANUFACTURERS STANDARDS |
| COMPLY WITH RAS 111 |
| MAXIMUM DESIGN PRESSURE OF -75, LIMITATION # 9 |
| THE SECOND ROOFING APPROVAL SUBMITTED IS NOA 12-0703.09 |
| PLEASE CIRCLE WHICH SUB-SYSTEM IS TO BE INSTALLED UNDER |
| THIS PERMIT. |
| |
| 5) 2ND REQUEST. SHEET S2.1 UNDER THE WIND LOAD SCHEDULE |
| NOTE # 1 INDICATES THE USE OF THE WORD EITHER SHUTTERS |
| OR LARGE MISSILE IMPACT TESTED ... |
| SHEET S2.1 THE WORD ?OR? IN THE WIND DESIGN SCHEDULE, |
| IMPACT GLASS OR SHUTTERS, SPECIFY ONE OR THE OTHER. |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. SUCH |
| DRAWINGS AND SPECIFICATIONS SHALL CONTAIN INFORMATION, |
| IN THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE CITED AS |
| A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. |
| |
| 6) SHEET LS 1.1, BUILDING CLASSIFICATION; |
| 6A-C) COMPLIED. |
| 6D) 2ND REQUEST. PLEASE UPDATE PLANS, THEY INDICATE A |
| LEVEL III ALTERATION THIS IS ALSO A CHANGE OF OCCUPANCY |
| AND THE 2010 EXST BLDG CODE CHANGE OF OCCUPANCY 901.3. |
| |
| 6E) 2ND REQUEST. OCCUPANT LOADS & EGRESS CAPACITY CHART |
| IS OFF WITH ONLY LOOKING AT THE REQUIRED WIDTH OF THE |
| STAIR, THE WORST CASE SCENARIO SHOULD BE THE DOOR, YOU |
| CAN?T BOTTLE NECK THE MEANS OF EGRESS, THE CHART SHOULD |
| BE REWORKED. |
| |
| 6F) SUBSTITUTION NOTE: 107.2.1 INFORMATION ON |
| CONSTRUCTION DOCUMENTS. SUCH DRAWINGS AND |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. |
| |
| 7) COMPLIED. |
| |
| 8) 2ND REQUEST. LS1.1, INDICATES 1 HR. GLASS WALL AT |
| STAIR # 1. ID 1.2 SI-9 APPEARS TO BE FOR WIRE GLASS |
| DETAIL AT STAIR # 1. PLEASE REVIEW THE MAXIMUM AREA |
| ALLOWED IN EXIT DOORS FBC-B 715.4.4, 715.4.4.1 715.4.5 |
| AS WELL AS TABLE 715.5.4 FOR WIRE GLASS PANELS AND |
| TABLE 715.5 FIRE WINDOW ASSEMBLIES IN FIRE BARRIERS (1 |
| HR. VERTICAL EXITS.) |
| |
| 9) 2ND REQUEST. SHEET LS1.1 INDICATES THE DOORS TO |
| STAIRWELL # 1 TO BE HELD OPEN. SHEET A10.1 THE DOORS |
| SCHEDULE TO STAIRWELL 1 ( 102.01) DO NOT INDICATE HOW |
| THEY ARE GOING TO STAY OPEN OR COMPLIANCE WITH FBC-B |
| 715.4.8. DOOR CLOSING, THIS REQUIREMENT WILL NEED TO BE |
| INDICATED FOR ALL STAIRWELL DOORS. NEITHER THE ELECTRIC |
| SHEETS OR FIRE ALARM SHOW ANY ELECTRIC TO THESE DOOR |
| FOR ELECTROMAGNETS AND RELEASE WHEN THE FIRE ALARM OR |
| FIRE SPRINKLERS ARE ACTIVATED. |
| |
| 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| |
| |
| |
| |
| |
| |