Plan Review Notes
Plan Review Notes For Permit 13060319
Permit Number 13060319
Review Stop B
Sequence Number 3
Notes
Date Text
2013-09-25 12:50:10****PROVISO****
 ****REVISION REQUIRED - REVISE PLAN TO SHOW
 COMPLIANCE****
 ****ISSUED AT CONTRACTOR'S RISK****
  
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FBC 1004.1, OCCUPANT LOAD TO BE NOT LESS THAN TABLE
 1004. MINIMUM OCCUPANT LOAD IS NOT CLEAR. FOR INSTANCE,
 AREA CALCS SHOW 442 SQUARE FEET LESS THAN THE TOTAL
 SQUARE FEET AREA. RECEPTION AREA DOES NOT APPEAR TO
 HAVE AN OCCUPANT LOAD, DINING AREA APPEARS TO BE
 UNDERSTATED (520 SF, WITHOUT FIXED SEATING, 15SF PER
 PERSON SHOULD BE 35, NOT 25). PLEASE REVISE. OCCUPANT
 LOAD OVER 50 WOULD BE A2, NOT M; SEE FBC CHAPTER 3. A2
 HAS ADDITIONAL REQUIREMENTS (PANIC DEVICES) FBC
 1008.1.10.
  
 4. SEE FBC 2010 EXISTING BUILDING CHAPTER 9. WHAT WAS
 THE PREVIOUS OCCUPANCY OF THE TWO SPACES? IF THIS IS A
 CHANGE OF OCCUPANCY, REVISE PLAN TO SHOW COMPLIANCE.
  
  
  