| REVIEW COMMENTS - FIRE DEPARTMENT |
| |
| *****NOTE: THIS IS A CHANGE OF USE/OCCUPANCY FROM |
| BUSINESS TO DAYCARE***** |
| |
| PROVIDE EMERGENCY LIGHTING. EMERGENCY ILLUMINATION |
| SHALL BE PROVIDED FOR A MINIMUM OF 1-1/2 HOURS IN THE |
| EVENT OF FAILURE OF NORMAL LIGHTING. EMERGENCY LIGHTING |
| FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL |
| ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 |
| FT-CANDLE AND, AT ANY POINT, NOT LESS THAN 0.1 |
| FT-CANDLE, MEASURED ALONG THE PATH OF EGRESS AT FLOOR |
| LEVEL. |
| |
| ARTWORK AND TEACHING MATERIALS ATTACHED TO THE WALLS |
| SHALL NOT EXCEED 20 PERCENT OF THE INDIVIDUAL WALL |
| AREA. |
| |
| SPECIAL PROTECTIVE COVERS FOR ALL ELECTRICAL |
| RECEPTACLES SHALL BE INSTALLED IN ALL AREAS OCCUPIED BY |
| CLIENTS. |
| |
| EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CLIENTS CAN |
| OPEN THE DOOR FROM INSIDE THE CLOSET. |
| |
| EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO ALLOW |
| OPENING OF THE LOCKED DOOR FROM THE OUTSIDE BY AN |
| OPENING DEVICE THAT SHALL BE READILY ACCESSIBLE TO THE |
| STAFF. |
| |
| AN EMERGENCY PLAN TO BE DEVELOPED AND POSTED IN |
| BUILDING PRIOR TO OCCUPANCY. EMERGENCY EGRESS DRILLS |
| SHALL BE CONDUCTED MONTHLY. |
| |
| FIRE PREVENTION INSPECTIONS SHALL BE CONDUCTED MONTHLY |
| BY A TRAINED SENIOR MEMBER OF THE STAFF, AFTER WHICH A |
| COPY OF THE LATEST INSPECTION REPORT SHALL BE POSTED IN |
| A CONSPICUOUS PLACE IN THE DAY-CARE FACILITY. IT SHALL |
| BE THE DUTY OF THE STAFF TO INSPECT ALL EXITS DAILY TO |
| ENSURE THAT ALL DOORS AND EXIT PATHS ARE MAINTAINED |
| CLEAR OF OBSTRUCTIONS. |
| |