Date |
Text |
2013-05-23 10:43:49 | BUILDING PLAN REVIEW |
| PERMIT: 13050463 |
| ADD: 4317 NORTHSHORE DR SUITE # |
| CONT: TBD |
| TEL: (561)574-8553 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: 5/23/2013 |
| ACTION: DENIED |
| |
| 1) THIS UNIT IS UNDERGOING A CHANGE OF OCCUPANCY FROM |
| BUSINESS TO DAYCARE, PLEASE SEE 2010 EXISTING BUILDING |
| CODE 901.3.1 PARTIAL CHANGE OF OCCUPANCY |
| CLASSIFICATION. |
| WHERE A PORTION OF AN EXISTING BUILDING IS CHANGED TO A |
| NEW OCCUPANCY CLASSIFICATION, SECTION 912 SHALL APPLY. |
| |
| 1A) EXST BLDG CODE 912.1.1.2 CHANGE OF OCCUPANCY |
| CLASSIFICATION WITH SEPARATION. WHERE A PORTION OF AN |
| EXISTING BUILDING THAT IS CHANGED TO A NEW OCCUPANCY |
| CLASSIFICATION AND THAT PORTION IS SEPARATED FROM THE |
| REMAINDER OF THE BUILDING WITH FIRE BARRIERS HAVING A |
| FIRE-RESISTANCE RATING AS REQUIRED IN THE FLORIDA |
| BUILDING CODE, BUILDING FOR THE SEPARATE OCCUPANCY, |
| THAT PORTION SHALL COMPLY WITH ALL THE REQUIREMENTS OF |
| CHAPTER 8 FOR THE NEW OCCUPANCY CLASSIFICATION AND WITH |
| THE REQUIREMENTS OF THIS CHAPTER. |
| |
| THE ADJACENT TENANTS ARE EITHER A BUSINESS OR |
| MERCANTILE OCCUPANCY THAT ONLY REQUIRE A ONE HOUR FIRE |
| SEPERATION BETWEEN OCCUPANCIES, PLEAS PROVIDE THE |
| FOLLOWING INFORMATION: |
| IS THIS BUILDING FIRE SPRINKLERED? |
| PROVIDE THE WALL SECTION AS TO WHAT TYPE OF WALL IS |
| THERE NOW A ONE HOUR RATED WALL OR A TWO HOUR RATED |
| WALL. IF WALL IS ONLY ONE HOUR RATED PLEASE PROVIDE A |
| WALL ASSEMBLY DETAIL FROM A RECONIZED NATIONAL TESTING |
| LAB FOR A 2 HOUR WALL RATING. 2010 FBC-B TABLE 508.4. |
| |
| 1B) EXST BLDG CODE 912.1.4 ACCESSIBILITY. ALL BUILDINGS |
| UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL |
| COMPLY WITH SECTION 912.8. 912.8 ACCESSIBILITY. |
| EXISTING BUILDINGS THAT UNDERGO A CHANGE OF GROUP OR |
| OCCUPANCY CLASSIFICATION SHALL COMPLY WITH THE |
| PROVISIONS OF THE FLORIDA BUILDING CODE, ACCESSIBILITY. |
| 202.4.1 DISPROPORTIONATE COST. |
| ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| AN INACCESSIBLE DRINKING FOUNTAIN. |
| |
| 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF |
| DISPROPORTIONALITY. |
| WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| ALARMS. |
| |
| 2) 2010 FBC-B436.2 CLOSET DOORS. EVERY CLOSET DOOR |
| LATCH SHALL BE SUCH THAT CLIENTS CAN OPEN THE DOOR FROM |
| INSIDE THE CLOSET. |
| |
| 3)2010 FBC-B 436.3 BATHROOM DOORS. EVERY BATHROOM DOOR |
| LOCK SHALL BE DESIGNED TO PERMIT OPENING OF THE LOCKED |
| DOOR FROM THE OUTSIDE IN AN EMERGENCY. THE OPENING |
| DEVICE SHALL BE READILY ACCESSIBLE TO THE STAFF. |
| |
| 4) 436.4 DOOR CLOSURE. ANY EXIT DOOR DESIGNED TO BE |
| NORMALLY CLOSED SHALL BE KEPT CLOSED AND SHALL COMPLY |
| WITH SECTION 715.3. |
| |
| 5) 2010 FBC-B 713.6 FIRE WALLS, FIRE BARRIERS, FIRE |
| PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY |
| OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE |
| EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR |
| STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY |
| HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE |
| ANY DECORATIVE CEILING AND IN CONCEALED SPACES. |
| SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: ?FIRE |
| AND SMOKE BARRIER ? PROTECT ALL OPENINGS.? |
| |
| 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| |
| |
| |
| |