Date Text
2013-05-07 11:16:414512 NORTH FLAGLER DRIVE - SUITE #201
 PERMIT #13050163
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET A-1.0: CONFERENCE ROOM #102 IS AN ASSEMBLY USE
 CALCULATED AT 15 SQ.FT. PER PERSON RESULTING IN AN
 OCCUPANT LOAD OF 18 PERSONS. PER SECTION 7.2.1.4.1, ANY
 DOOR ASSEMBLY IN A MEANS OF EGRESS SHALL BE OF THE
 SIDE-HINGED OR PIVOTED SWINGING TYPE, AND SHALL BE
 INSTALLED TO BE CAPABLE OF SWINGING FROM ANY POSITION
 TO THE FULL REQUIRED WIDTH OF THE OPENING IN WHICH IT
 IS INSTALLED. BUSINESS AREAS WITH AN OCCUPANT LOAD NOT
 EXCEEDING 10 PERMITS HORIZONTAL-SLIDING DOOR
 ASSEMBLIES.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  