Plan Review Notes For Permit 13041140 |
Permit Number |
13041140 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2013-05-06 12:41:30 | FBC 2010 EXISTING BUILDING CODE | | FBC 2010 ACCESSIBILITY CODE | | FBC 2010 PLUMBING REVIEW #1 | | PENDING : | | | | PLEASE SEE BUILDING REVIEW COMMENTS ON ACCESSIBILITY. | | | | ***NOTE*** | | TWO DRINKING FOUNTAINS ARE SHOWN AS EXISTING. IF THESE | | ARE SET AT WHEELCHAIR HEIGHT, THE NEW DRINKING FOUNTAIN | | SHOULD BE A HI/LO DRINKING FOUNTAIN PER ACCESSIBILITY | | 211.2 OR A SINGLE FOUNTAIN SET AT A HEIGHT TO COMPLY | | WITH ACCESSIBILITY 602.7 | | | | 211.2 MINIMUM NUMBER. | | NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. | | ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH | | 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH | | 602.7. | | 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. | | SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING | | PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 | | INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | |
|