2013-05-02 15:22:42 | BUILDING PLAN REVIEW |
| PERMIT: 13041140 |
| ADD: 400 CLEMATIS ST SUITE # 101 |
| CONT: JOE SCHMIDT CONSTRUCTION INC. |
| TEL: (561)248-8860 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: 5/02/ 2013 |
| ACTION: DENIED |
| |
| 1) THE SUBMITTED PLAN DOES NOT CLEARLY STATE WHERE WORK |
| IS GOING TO BE ACCOMPLISHED UNDER THIS PERMIT. THE NEW |
| CAMP ULTIMA IS A CHANGE OF OCCUPANCYTHE LAST KNOWN |
| OCCUPANCY IN THIS SPACE WAS A RESTARAUNT, IF OCCUPANT |
| LOAD UNDER 50 THEN CONSIDERED MERCANTILE IF OVER 50 |
| THEN IT WOULD OF BEEN CONSIDERED A2 ASSEMBLY |
| RESTARAUNT. THE NEW OCCUPANCY IS TO BE A GYM WHICH IS A |
| A3 OCCUPANCY. 2010 FLORIDA EXISTING BUILDING CODE |
| SECTION 901.3.1 PARTIAL CHANGE OF OCCUPANCY |
| CLASSIFICATION. WHERE A PORTION OF AN EXISTING BUILDING |
| IS CHANGED TO A NEW OCCUPANCY CLASSIFICATION, SECTION |
| 912 SHALL APPLY. |
| |
| 2) 912.1.2 FIRE PROTECTION AND INTERIOR FINISH. |
| THE PROVISIONS OF SECTIONS 912.2 AND 912.3 FOR FIRE |
| PROTECTION AND INTERIOR FINISH, RESPECTIVELY, SHALL |
| APPLY TO ALL BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY |
| CLASSIFICATION. |
| |
| 912.2 FIRE PROTECTION SYSTEMS. |
| FIRE PROTECTION SYSTEMS SHALL BE PROVIDED IN ACCORDANCE |
| WITH SECTIONS 912.2.1 AND 912.2.2. |
| |
| 912.2.2 FIRE ALARM AND DETECTION SYSTEM. |
| WHERE A CHANGE IN OCCUPANCY CLASSIFICATION OCCURS THAT |
| REQUIRES A FIRE ALARM AND DETECTION SYSTEM TO BE |
| PROVIDED BASED ON THE NEW OCCUPANCY IN ACCORDANCE WITH |
| CHAPTER 9 OF THE FLORIDA BUILDING CODE, BUILDING, SUCH |
| SYSTEM SHALL BE PROVIDED THROUGHOUT THE AREA WHERE THE |
| CHANGE OF OCCUPANCY OCCURS. EXISTING ALARM NOTIFICATION |
| APPLIANCES SHALL BE AUTOMATICALLY ACTIVATED THROUGHOUT |
| THE BUILDING. WHERE THE BUILDING IS NOT EQUIPPED WITH A |
| FIRE ALARM SYSTEM, ALARM NOTIFICATION APPLIANCES SHALL |
| BE PROVIDED THROUGHOUT THE AREA WHERE THE CHANGE OF |
| OCCUPANCY OCCURS AND SHALL BE AUTOMATICALLY ACTIVATED. |
| PLANS DO NOT INDICATE IF THERE IS A FIRE SPRINKLER |
| SYSTEM WITHIN THIS BUILDING. |
| |
| 912.3 INTERIOR FINISH. |
| IN AREAS OF THE BUILDING UNDERGOING THE CHANGE OF |
| OCCUPANCY CLASSIFICATION, THE INTERIOR FINISH OF WALLS |
| AND CEILINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING FOR THE NEW OCCUPANCY |
| CLASSIFICATION. |
| |
| 3) 912.1.4 ACCESSIBILITY. |
| ALL BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY |
| CLASSIFICATION SHALL COMPLY WITH SECTION 912.8. 912.8 |
| ACCESSIBILITY. EXISTING BUILDINGS THAT UNDERGO A CHANGE |
| OF GROUP OR OCCUPANCY CLASSIFICATION SHALL COMPLY WITH |
| THE PROVISIONS OF THE FLORIDA BUILDING CODE, |
| ACCESSIBILITY. |
| |
| 3A) 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. THE NEW |
| RECEPTIONIST COUNTER DOES NOT COMPLY WITH 2010 FL |
| ACCESSIBILITY CODE |
| 904.3.3 CHECK WRITING SURFACES. WHERE PROVIDED, CHECK |
| WRITING SURFACES SHALL COMPLY WITH 902.3. 902.3 HEIGHT. |
| THE TOPS OF WORK SURFACES SHALL BE 28 INCHES (710 MM) |
| MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR OR GROUND. |
| |
| 3B) 2010 FL ACCESSIBILITY CODE 202.4.1 DISPROPORTIONATE |
| COST. |
| ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| AN INACCESSIBLE DRINKING FOUNTAIN. |
| |
| 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF |
| DISPROPORTIONALITY. |
| WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH |
| OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE |
| ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE |
| ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE |
| FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN |
| ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST |
| ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX |
| RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE |
| DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL |
| ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND |
| ALARMS. |
| |
| PLEASE PROVIDE A ITEMIXED LIST WHERE AN ADDITIONAL |
| $18,000.00 DOLLARS WILL BE SPENT IN ACCESSIBILITY |
| UPGRADES TO THE ALTERED WORK AREAS. NOTE IF THE |
| ACCESSIBLE ENTRANCE AND AND ACCESSIBLE ROUTE TO ALTERED |
| AREAS DO NOT NEED ACCESSIBILITY UPDATES THEN THE |
| RESTROOMS IN THE NEWLY CHANGED OCCUPANCY WOULD NEED TO |
| SPEND AN ADDITIONAL $18,000.00 IN ACCESSIBILITY |
| UPGRADES. |
| |
| 4) PLEASE PROVIDE STRUCTURAL DETAILS HOW THE PROPOSED |
| NEW DOORWAY WILL OCCUR STRUCTURALLY ? 107.2.1.3 |
| ADDITIONAL INFORMATION REQUIRED. |
| |
| 5) PLEASE PROVIDE A LIFE SAFETY PLAN AND OCCUPANT COUNT |
| FOR THE VARIOUS AREAS OF THE TENANT SPACE PLEASE USE |
| TABLE 1004.1.1 FBC-B TO FIGURE WHAT THE TOTAL OCCUPANT |
| LOAD WILL BE ? |
| |
| 6) THE PLANS DO NOT INDICATE ANY EXIT LIGHTS, |
| DIRECTIONALS NOR EMERGENCY LIGHTING FOR THIS TENANT |
| 2010 FBC-B 1006.3 EXIT SIGNS & 1006.1.6.2 SOURCES OF |
| ILLUMINATION, BATTERY BACK UP? |
| |
| 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |
| 6) |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |