2013-04-29 09:13:07 | BUILDING PLAN REVIEW | | PERMIT: 13040768 | | ADD:777 S FLAGLER # 140E | | CONT: BUTLER CONSTRUCTION CO. | | TEL: (561)832-9700 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: 4-29/2013 | | ACTION: BUILDING PROVISO | | | | 1) EXISTING GLASS DOORS BETWEEN THE VESTIBULE 100 & | | RECEPTION ROOM 101 SWING THE WRONG WAY TO BE CONSIDERED | | PART OF AN EXIT. THE COVERSHEET HAS AN EXIT LIGHT | | DIRECTLY ABOVE THESE DOORS, TO MAKE THIS A CODE | | COMPLIANT ELEMENT EITHER: | | 1) REMOVE THE EXIT LIGHT ABOVE THE GLASS DOORS, IS NOT | | REQUIRED TO BE A MEANS OF EGRESS OR, | | 2) REVERSE THE SWING OF THE DOORS TO OUT SWING DOORS. | | 2010 FBC-B 1008.1.2 DOOR SWING- DOORS SHALL SWING IN | | THE DIRECTION OF EGRESS TRAVEL WHERE SERVING AN | | OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H | | OCCUPANCY. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|