2013-04-12 11:20:06 | BUILDING PLAN REVIEW |
| PERMIT: 13040089 |
| ADD: 400 N FLAGLER PH#B4 |
| CONT: A D SABA ENTERPRISES |
| TEL: (561)307-5358 |
| |
| 2010 FLORIDA BUILDING CODE W |
| * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| |
| 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: 4/12/ 2013 |
| ACTION: BUILDING PROVISO: |
| BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| THESE DOCUMENTS LISTED BELOW MUST BE SUBMITTED BEFORE |
| FRAMING INSPECTION TO THE BUILDING DEPARTMENT. |
| |
| 1) SUBMIT MANUFACTURERS SPECIFICATIONS MEETING THE |
| SOUND DEADENING REQUIREMENT FOR (WOOD FLOORS & TILE ) |
| 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| |
| 2) HIGH RISE REQUIREMENTS :2010 FBC 603.1 ALLOWABLE |
| MATERIALS. |
| COMBUSTIBLE MATERIALS SHALL BE PERMITTED IN BUILDINGS |
| OF TYPE I OR II CONSTRUCTION IN THE FOLLOWING |
| APPLICATIONS AND IN ACCORDANCE WITH SECTIONS 603.1.1 |
| THROUGH 603.1.3: |
| |
| |
| 2A) TILE AAND OR MARBLE FLOORS EXCEPTION1.INSULATION |
| PLACED BETWEEN TWO LAYERS OF NONCOMBUSTIBLE MATERIALS |
| WITHOUT AN INTERVENING AIRSPACE SHALL BE ALLOWED TO |
| HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 100. |
| |
| 2B) WOOD FLOORS, SECTION 805 COMBUSTIBLE MATERIALS IN |
| TYPES I AND II CONSTRUCTION |
| 805.1.3 INSULATING BOARDS. COMBUSTIBLE INSULATING |
| BOARDS NOT MORE THAN 1/2 INCH (12.7 MM) THICK AND |
| COVERED WITH FINISH FLOORING ARE PERMITTED WHERE |
| ATTACHED DIRECTLY TO A NONCOMBUSTIBLE FLOOR ASSEMBLY. |
| |