Plan Review Notes
Plan Review Notes For Permit 13040089
Permit Number 13040089
Review Stop B
Sequence Number 1
Notes
Date Text
2013-04-12 11:20:06BUILDING PLAN REVIEW
 PERMIT: 13040089
 ADD: 400 N FLAGLER PH#B4
 CONT: A D SABA ENTERPRISES
 TEL: (561)307-5358
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 4/12/ 2013
 ACTION: BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
 THESE DOCUMENTS LISTED BELOW MUST BE SUBMITTED BEFORE
 FRAMING INSPECTION TO THE BUILDING DEPARTMENT.
  
 1) SUBMIT MANUFACTURERS SPECIFICATIONS MEETING THE
 SOUND DEADENING REQUIREMENT FOR (WOOD FLOORS & TILE )
 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2) HIGH RISE REQUIREMENTS :2010 FBC 603.1 ALLOWABLE
 MATERIALS.
 COMBUSTIBLE MATERIALS SHALL BE PERMITTED IN BUILDINGS
 OF TYPE I OR II CONSTRUCTION IN THE FOLLOWING
 APPLICATIONS AND IN ACCORDANCE WITH SECTIONS 603.1.1
 THROUGH 603.1.3:
  
  
 2A) TILE AAND OR MARBLE FLOORS EXCEPTION1.INSULATION
 PLACED BETWEEN TWO LAYERS OF NONCOMBUSTIBLE MATERIALS
 WITHOUT AN INTERVENING AIRSPACE SHALL BE ALLOWED TO
 HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 100.
  
 2B) WOOD FLOORS, SECTION 805 COMBUSTIBLE MATERIALS IN
 TYPES I AND II CONSTRUCTION
 805.1.3 INSULATING BOARDS. COMBUSTIBLE INSULATING
 BOARDS NOT MORE THAN 1/2 INCH (12.7 MM) THICK AND
 COVERED WITH FINISH FLOORING ARE PERMITTED WHERE
 ATTACHED DIRECTLY TO A NONCOMBUSTIBLE FLOOR ASSEMBLY.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676